Balluff Network Interface 

ProfiNet™

 

www.balluff.com 

 

 

 

2

 

Safety 

2.1.

 

Intended use 

  The BNI PNT-

… is a decentral IO-Link input and output module for connecting to a 

ProfiNet™ network. 

 

2.2.

 

Installation and 
Startup 

 

Attention! 

Installation and startup are to be performed by trained technical personnel only. 
Skilled specialists are people who are familiar with the work such as installation 
and the operation of the product and have the necessary qualifications for these 
tasks. Any damage resulting from unauthorized tampering or improper use shall 
void warranty and liability claims against the manufacturer. The operator is 
responsible for ensuring that the valid safety and accident prevention regulations 
are observed in specific individual cases. 

 

2.3.

 

General Safety 
Notes 

 

Commissioning and inspection 

Before commissioning, carefully read the User's Guide. 
The system must not be used in applications in which the safety of persons depends on the 
function of the device. 

Intended use 

Warranty and liability claims against the manufacturer shall be rendered void by damage 
from: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this User's 
Guide. 

Obligations of the owner/operator! 

The device is a piece of equipment in accordance with EMC Class A. This device can 
produce RF noise. The owner/operator must take appropriate precautionary measures 
against this for its use. The device may be used only with a power supply approved for this. 
Only approved cables may be connected. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 
Approved use is ensured only when the housing is 
fully installed. 

 

2.4.

 

Resistance to 
Aggressive 
Substances 

 

 

Attention! 

The BNI modules always have good chemical and oil resistance. When used in 
aggressive media (such as chemicals, oils, lubricants and coolants, each in a high 
concentration (i.e. too little water content)), the material must first be checked for 
resistance in the particular application. No defect claims may be asserted in the 
event of a failure or damage to the BNI modules caused by such aggressive 
media.

 

 

 

Dangerous 
Voltage 

 

Attention! 

Before working on the device, switch off its power supply. 

 

 

 

Note 

In the interest of continuous improvement of the product, 
Balluff GmbH reserves the right to change the technical data of the product and 
the content of these instructions at any time without notice. 

 
 
 

Содержание BNI PNT-508-005-E002

Страница 1: ...BNI PNT 508 005 E002 IP69 Modules User s Guide...

Страница 2: ...pply 7 Grounding 7 PROFINET interface 7 I O port 8 IO Link Port 8 Port 8 4 Technical data 9 4 1 Dimensions 9 4 2 Mechanical Data 9 4 3 Operating conditions 9 4 4 Electrical Data 9 4 5 PROFINET 10 4 6...

Страница 3: ...23 Write 23 7 Monitoring Diagnostics 24 7 1 General 24 7 2 SNMP MIBs 24 8 Diagnostics 26 8 1 Diagnostics message 26 8 2 Block Header 27 Block Type 27 Block Length 27 Block Version High 27 Block Versi...

Страница 4: ...m 3 No appropriate IODD uploaded 38 Appropriate IODD uploaded 39 9 6 IODD dialog 41 9 7 Config dialog 42 9 8 Log dialog 44 10 Appendix 46 10 1 Scope of Delivery 46 10 2 Order number 46 10 3 Ordering i...

Страница 5: ...Step 2 3 Syntax Numbers Decimal numbers are shown without additional information e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex or the prefix 0x e g 0x00 Cross refe...

Страница 6: ...the instructions provided in this User s Guide Obligations of the owner operator The device is a piece of equipment in accordance with EMC Class A This device can produce RF noise The owner operator...

Страница 7: ...e 1 Overview of BNI PNT 50x 105 Z015 1 Mounting hole 2 PROFINET port 2 3 Power IN 4 Status LEDs 5 Port 1 6 Pin Port LEDs 7 Port 3 8 Port 5 9 Port 7 10 Port 6 11 Port 4 12 Port 2 13 Port 0 14 Power OUT...

Страница 8: ...er supply ground 0 V 2 3 Function ground FE 4 Bus sensor power supply 24 V 5 Actuator power supply 24 V Note Where possible use separate power supplies for sensor bus and actuator Total current 9 A Th...

Страница 9: ...ts EN 61131 2 Type 3 Note Each output draws a maximum current of 2 A The maximum total current of all module outputs must not exceed 9A Note Unused ports must be provided with cover caps in order to e...

Страница 10: ...pply voltage 7 8 5 pin male female Input ports output ports M12 A coded 8x female Dimensions W x H x D in mm 70 x 224 x 41 1 Type of mounting Screw mounting with 2 mounting holes Weight Approx 670 gr...

Страница 11: ...e Class B Netload Class 3 4 6 Function indicators Module Status LED Indicator Function US Green Input voltage OK Red Input voltage low 18 V UA Green Output voltage OK Red flashing Output voltage low 1...

Страница 12: ...rt circuit at the output on pin 2 4 to pin 3 Red No high signal at diagnostic input IO Link port Status Function Green IO Link connection active Green flashing No IO Link connection or wrong IO Link d...

Страница 13: ...configuration of the IO Link blocks the corresponding data modules are assigned to a slot Integration of the module The device can be found by searching in the catalog and inserted in the Profinet se...

Страница 14: ...ter tab to open a menu selection for defining the port functions and diagnostic functions Note IO Link configuration If the connected IO Link device makes outputs available pin 2 must be configured to...

Страница 15: ...nfiguring the IO Link module A suitable IO Link module that corresponds to the process data length of the IO Link device must be selected in the catalog and dragged to the appropriate slot by means of...

Страница 16: ...length the actual process data length of the IO Link device is entered These settings are only for the input data The visible data window for the input data can now be adjusted via an IO Link module w...

Страница 17: ...com 16 5 Integration Device name Profinet address Double click on the module in the Profinet line to view the communication parameters of the module The device name and the Profinet address IP are con...

Страница 18: ...odule Assign device name Assigning device name Select the desired name and use Assign name to assign the marked device that you found The device name must be the same as that previously configured und...

Страница 19: ...nk device connected IO Link device fault e g external voltage supply not connected Validation failed If the module still reports a bus error there could be a problem in one of the following areas Devi...

Страница 20: ...n be used to permit suppress the diagnostics message Sensor Short circuit on the module output Visual diagnostics and diagnostics in configured diagnostics modules is not affected Function applies onl...

Страница 21: ...down pin 4 pin 2 Depicts a short circuit between a set output to ground at the respective port pin Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1 Port...

Страница 22: ...eripheral error socket Feedback indicating the port at which an error occurred Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1 Port 0 Short circuit Sen...

Страница 23: ...s performed As soon as the saved parameter data in the port parameter server differs from the that of the connected IO Link device and no upload requests from the IO Link device are present a download...

Страница 24: ...xed 1 0 1 63 64 255 IOL master Port number Reserved 2 65098 FI_Index IO Link header is following IO Link header 1 0 255 Task 2 write 3 read 2 0 3276 7 65535 IO Link index Port function 1 0 255 IO Link...

Страница 25: ...and diagnostics of the device network settings can be done over the network using the SNMPv1 protocol This can be accessed simply from a so called SNMP browser or common network management application...

Страница 26: ...s assigned to this port This object may contain an octet string of zero length since IO Link is a serial P2P protocol with no specific addressing ifAdminStatus Up 1 Down 2 depending Up 1 Down 2 depend...

Страница 27: ...ed into 3 blocks Block Header Alarm Specifier Channel Properties Byte Value Meaning Block 0 00 Block Type Block Header 1 02 2 00 Block Length 3 1E 4 01 Block Version High 5 00 Block Version Low 6 00 A...

Страница 28: ...s default is 0 Possible values Meaning 0x00000000 Default value Slot 2 bytes of data that describe which slot of the module reports an error BNI PNT 508 005 E002 Possible values Meaning 0x0001 Slot 1...

Страница 29: ...0x00000038 IOL IN 0 OUT 16 0x0000003F IOL IN 0 OUT 24 0x0000002C IOL IN 0 OUT 32 0x0000002D IOL IN 1 OUT 1 0x0000002E IOL IN 2 OUT 2 0x00000040 IOL IN 2 OUT 4 0x00000041 IOL IN 4 OUT 2 0x00000042 IOL...

Страница 30: ...t 12 Possible values Meaning 0x00 No diagnosis related to manufacturer is pending 0x01 Diagnosis related to channel is pending Submodules Diagnostic State Bit 13 Possible values Meaning 0x00 No furthe...

Страница 31: ...0 n Actor Short circuit Pin 2 3 0 n Actor Short circuit Pin 4 3 0 n n Number of IOL Ports Configuration as IO Link Error Type Channel Number Line break 0 Short circuit IOL Pin 4 3 0 Sensor short circ...

Страница 32: ...it 0x05 16 Bit 0x06 32 bit 0x07 64 bit 0x08 0xFF Reserved Accumulative Bit 8 not used always 0 Maintenance Bit 9 10 Possible values Meaning Bit 9 Bit 10 0x00 0x00 Diagnostics Specifier Bit 11 12 Possi...

Страница 33: ...ltage 0x0003 Overvoltage 0x0004 Overload 0x0005 Temperature limit exceeded 0x0006 Cable break 0x0007 Upper threshold exceeded 0x0008 Lower threshold undershot 0x0009 Error 0x001A External error 0x001B...

Страница 34: ...st ensure that the module has been correctly integrated into your network In addition the IP subnet of the BNI module must be accessible from the PC on which the browser is running Please use Internet...

Страница 35: ...the upper area of the window which allows you to switch between the various dialogs of the web interface To do this click on the corresponding icon When the Info tab is selected the following overview...

Страница 36: ...T XXX XXX XXXX BNIPNT BNI EIP XXX XXX XXXX BNIEIP BNI ECT XXX XXX XXXX BNIECT The password cannot be changed After successfully logging in the dialogs are shown as follows Use the Logout button to log...

Страница 37: ...ion is also shown about the current process data and the status of the module via the corresponding LEDs After selecting LED Legend a Help dialog appears which explains the meaning of the LEDs If an I...

Страница 38: ...Balluff Network Interface ProfiNet www balluff com 37 9 Webserver PNT EIP...

Страница 39: ...o appropriate IODD uploaded It is possible to read and write the configuration parameters of the IO Link device via the Parameters option The parameter indexes and subindexes of the IO Link device are...

Страница 40: ...for Process Data and Parameters is not displayed but rather an expanded dialog Information from the IODD of the device is used so that the data can be better understood Thus in the following screensh...

Страница 41: ...nt modes These modes can be set using an IO Link parameter The parameter values and associated texts are stored in the IODD This means Operation Mode can be read out and displayed Read and Read All bu...

Страница 42: ...at i e with a restricted name length Since IODD files are generally published with a long file name these must be renamed and given a shorter naming scheme on the PC before uploading to the fieldbus m...

Страница 43: ...The configuration page enables configuration of the module You can change both the module information texts and the port configuration The Set Ports action is not permanently stored in the device and...

Страница 44: ...e Configuration and permanently stored in the device The Reboot button reboots the device as if the power to the module had been turned off and on again Clicking on Factory Reset deletes the configura...

Страница 45: ...upper table see screenshot below contains important information for all service inquiries Note If you have a detailed question about a specific situation send us a screenshot of this Web site or print...

Страница 46: ...ting the module from the outside The system may require troubleshooting Event Informational Notice The fieldbus module has detected an important normal operating event and reports it These may include...

Страница 47: ...ff Network Interface ProfiNet Functions 508 IP 69 IO Link master module 8 IO Link ports Variants 005 2 Port Switch Mechanical Version E002 stainless steel housing V4A Data transmission 2 x M12x1 inter...

Страница 48: ...7 www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 932275 726 E 01 124840 Edition I17 Replaces Edition K16 Subject...

Отзывы: