www.balluff.com
10
4
Technical data
4.5.
PROFINET
PROFINET port
100Base-Tx
Connection for PROFINET port M12, D-coded, female
Cable types in accordance with
IEEE 802.3
Shielded, twisted pair min. STP CAT 5/ STP CAT 5e
Data transmission rate
100 Mbps
Max. cable length
100 m
Flow control
Full-duplex (IEEE 802.33x-Pause)
Profinet Conformance-Class
B
Netload-Class
3
4.6.
Function
indicators
Module Status
LED
Indicator
Function
US
Green
Input voltage OK
Red
Input voltage low (< 18 V)
UA
Green
Output voltage OK
Red, flashing
Output voltage low (< 18 V)
Red
Output voltage < 11 V
SF
Off
No error
Red
Diagnostics present; system error
Red, flashing
Service DCP signal started via bus
BF
Off
No error
Red
No connection or no configuration
Red, flashing
No data exchange
100
Off
Transmission rate: 10 Mbit/s
Yellow
Transmission rate: 100 Mbit/s
LK
Green
Data transfer
Status LEDs
Port LEDs