BIS V-6106 Ethernet/IP™
Processor Unit
9
For BIS V-6106-034-C00_, read/write heads in the BIS VM-3 _ _, BIS VL-3 _ _, and BIS VU-3 _ _
series can be connected to terminals H1...H4. BIS V-6106-034-C10_ also supports read/write
heads in the BIS C-3 _ _ series (Adapter required).
Note
Read/write heads in the BIS VU-3 _ _ series are only supported with a device software
version of 3.0 or higher. Should the occasion arise, an update will be required.
Note
Device software as well as manuals with detailed information about the read/write
heads used are available at
www.balluff.com
.
BIS V processor units are available in different variants with respect to the supported read/write
heads. The following table shows the differences.
Processor Unit
Available Connections
Compatible Read/Write Heads
H1…H4
VM-3
_ _
VL-3
_ _
VU-3
_ _
C-3
_ _
BIS V-6106-034-C002
H1…H4
YES
YES
YES
NO
BIS V-6106-034-C102
H1…H4
YES
YES
YES
YES
Note
Only shielded cables are to be used for connecting read/write heads!
An adapter cable is required for connecting read/write heads in the BIS C-3_ _ series.
The maximum cable length for read/write heads in the BIS VM-3 _ _, BIS VL-3 _ _,
and BIS VU-3 _ _ series is 50 m. For the BIS C-3 _ _ series, the cable length is set at
1 m, 5 m, or 10 m plus the adapter depending on the design of the system.
Note
Visit
www.balluff.com
for more information on available software and accessories.
Ethernet/IP is an industrial networking standard. The IP in Ethernet/IP stands for "Industrial
Protocol". Ethernet/IP uses the "Common Industrial Protocol" (CIP) open communication
protocol at the application tier (in accordance with ISO/OSI reference model).
Ethernet/IP is supported by the "Open DeviceNet Vendor Association" (ODVA) network
organization.
3.5 Read/Write
Heads H1…H4
3.6 EtherNet/IP™
3
Basic
Knowledge