www.balluff.com
BIS V-6106 Ethernet/IP™
Processor Unit
25
The control commands for the identification system and the data to be written to the data carrier
are transmitted via the output buffer.
Bit No.
Subaddress
7
6
5
4
3
2
1
0
00
hex
= Bit
Header
TI
KA
GR
AV
01
hex
Command Identifier
or
Data
02
hex
Start address (Low Byte) or program No.
or
Data
03
hex
Start address (high byte)
or
Data
04
hex
Number of bytes (low byte)
or
Data
05
hex
Number of bytes (high byte)
or
Data
06
hex
Data
…
Data
Last Byte = Bit
Header
TI
KA
GR
AV
Assignment and explanation
Subaddress
Bit name
Meaning
Description of Function
00
hex
/last
byte
TI
Toggle Bit In
Controller is ready to receive additional data
(read job).
KA
Head shutoff
Shuts off the R/W head's antenna. Tag
detection no longer takes place. CP and MT
are 0.
GR
Default state
Cancels the current job for this R/W head
and puts the channel into a basic state. The
R/W head can then be used again once
GR = 0 and the controller has acknowledged
this with BB = 1. CP and MT are 0.
AV
Job
A job is present.
7.2 Process
Data
Buffer
Output buffer
7
Device
Functions