Mifare:
Read times Data carrier with 16 bytes per block
Data carrier detection
~ 20 ms
Read bytes 0 to 15
~ 25 ms
For each additional 16-byte block started
~ 10 ms
Write times Data carrier with 16 bytes per block
Data carrier detection
~ 20 ms
Write bytes 0 to 15
~ 60 ms
For each additional 16-byte block started
~ 30 ms
ISO 15693:
Read times Data carrier with 16 bytes per block
Data carrier detection
~ 20 ms
Read bytes 0 to 15
~ 25 ms
For each additional 16-byte block started
~ 10 ms
Write times Data carrier with 16 bytes per block
FRAM
(BIS M-1_ _-02/20)
EEPROM
(BIS M-1_ _-03/07/08)
Data carrier detection
~ 20 ms
~ 20 ms
Write bytes 0 to 15
~ 60 ms
~ 80 ms
For each additional 16-byte block started
~ 25 ms
~ 80 ms
High speed*:
Read times Data carrier with 64 bytes per block
Data carrier detection
~ 20 ms
Read bytes 0 to 63
~ 14 ms
For each additional 64-byte block started
~ 6 ms
Write times Data carrier with 64 bytes per block
Data carrier detection
~ 20 ms
Write bytes 0 to 15
~ 30 ms
For each additional 64-byte block started
~ 15 ms
*These times apply only for the combination of BIS VM-3_ _-401-S4 read/write head with
BIS M-1_ _-11/A, BIS M-1_ _-13/A, BIS M-1_ _-14/A, or BIS M-1_ _-15/A data carriers.