www.balluff.com
63
english
6.7.5 System Commands
Command Value Device Action
0x81 (129)
Application Reset
– Resets the
Voltage Monitoring Detection Time
Duration
with ISDU-index 0x2200 to
the default value 10.
0x82 (130)
Restore Factory Settings
– Resets
the
Voltage Monitoring Detection
Time Duration
with ISDU-index
0x2200 to the default value 10.
Tab. 6-35: Voltage and current monitoring – System Commands
For an overview of all System Commands, see section 3.5
6.7.6 Events
Event Code
Event Type
Event – Description – Remedy
Device Status
0x5110
(20752)
Warning
Primary supply voltage exceeded
►
Check for deviations in the supply.
2 – Out-of-Specification
0x5111
(20753)
Warning
Primary supply voltage below minimum value
►
Check for deviations in the supply.
2 – Out-of-Specification
0x8D0B
(36107)
Warning
Overload or short circuit at pin 2
►
Check wiring.
2 – Out-of-Specification
0x8D0D
(36109)
Warning
Incorrect load/cable breakage, analog current output pin 2
►
Check wiring or connected devices.
2 – Out-of-Specification
0x8D15
(36117)
Warning
Overload at pin 2
►
Check wiring.
2 – Out-of-Specification
Tab. 6-36: Voltage and current monitoring – Events
6
Secondary Device Functions (continued)
BCS Q40BBAA-PIM20C-EP _ _ _ -GS04
Capacitive Proximity Switches
Содержание BCS Q40BBAA-PIM20C-EP-GS04 Series
Страница 1: ...BCS Q40BBAA PIM20C EP___ GS04 deutsch Konfigurationsanleitung english Configuration Guide...
Страница 2: ...www balluff com...
Страница 3: ...BCS Q40BBAA PIM20C EP___ GS04 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 87: ...BCS Q40BBAA PIM20C EP___ GS04 Configuration Guide english...
Страница 88: ...www balluff com...
Страница 171: ......