www.balluff.com
23
english
Event Code Event Type
Event – Description – Remedy
Device Status
0x8D18
(36120)
Notification
One of the Switching Counter channels reached its
set limit.
►
Check Switching Counter.
0 – Device is operating properly.
0x8D19
(36121)
Warning
One of the Switching Counter channels reached the
maximum counter value.
►
Check Switching Counter.
0 – Device is operating properly.
0x8D20
(36128)
Warning
Device Temperature Lower Warning
– The set lower
temperature warning threshold is below the minimum
value.
0 – Device is operating properly.
0x8D22
(36130)
Warning
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
0 – Device is operating properly.
0x8D23
(36131)
Error
Write cycle limit reached – saving no longer ensured
– replacement recommended.
1 – Maintenance-Required
0x8D24
(36132)
Warning
Parameter write error – for information purposes
only.
0 – Device is operating properly.
0x8D25
(36133)
Error
Parameters not consistent – basic settings are used,
service required. Parameterization processes and
resets can no longer be performed.
4 – Failure
0x8D26
(36134)
Warning
User data was reset to the default settings.
►
Check settings and acknowledge warning.
1 - Maintenance required
0x8DC0
(36288)
Notification
Teach-in Timeout
– The current teach-in process
took too long and was interrupted.
0 – Device is operating properly.
Tab. 3-9: Events – Overview
3
Overview of IO-Link Data and Functions (continued)
BCS Q40BBAA-PIM20C-EP _ _ _ -GS04
Capacitive Proximity Switches
Содержание BCS Q40BBAA-PIM20C-EP-GS04 Series
Страница 1: ...BCS Q40BBAA PIM20C EP___ GS04 deutsch Konfigurationsanleitung english Configuration Guide...
Страница 2: ...www balluff com...
Страница 3: ...BCS Q40BBAA PIM20C EP___ GS04 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 87: ...BCS Q40BBAA PIM20C EP___ GS04 Configuration Guide english...
Страница 88: ...www balluff com...
Страница 171: ......