8  Safety measures 

 
 

Prior to cleaning disconnect the heater from the mains. 
Loosen  the  spacer  screws  on  the  latches.  Lower  two 
latches «Р» (see Fig. 6) on the rear panel of the heater 
and  pull  the  device  to  yourself.  Remove  the  device 
from  the  brackets  and  clean  the  rear  panel.  After 
cleaning  the  heater  should  be mounted in  the  reverse 
order. 
 

Safety measures 
 

 

Fix the heater reliably on the wall or place it in the 
correct position. 

 

The  heater  should  be  installed  in  such  a  way  so 
that  a  person  in  the  bath  or  shower  could  not 
accidentally touch the control panel. 

 

It  is  forbidden  to  place  the  heater  under  the 
mains socket. 

 

If  the  heater is  placed  on  the  floor,  keep  it  away 
from the bath, shower or swimming pool. 

 

If  wall-mounted,  never  locate  the  heater  in  the 
vicinity of the bath, shower or the swimming pool. 

 

If the power cable is damaged, contact a qualified 
electrician or a service person. 

 

NEVER cover the working heater. 

 

Before storage arrangements ensure the heater is 
cool. 

 

If  the  heater  is  not  intended  for  use  for  a  long 
time  it  is  recommended  to  clean  it  and  put  for 
storage  (preferably  in  the  factory  package)  in  a 
cool dry place. 

 

Maintenance 
 

If  maintenance  is  necessary,  contact  the  authorized 
service center. 
 
 
Power cable replacement 
To avoid accidents the damaged power cable should  

be  replaced  by  the  service  centre  representative  or 
another qualified specialist. 
 

Installation 
 

1.

 

Wall mount. Install the heater on the wall near the 

floor  using  the  brackets  according  to  the figures  below. 
The  distance  from  the  device  to  the  floor  should  be  at 
least 10 cm. 

 

 

 

Fig. 7 

 
The wall bracket can be released from the convector as 
follows: 

 

press the latches and pull the bracket to yourself; 

 

mark and drill the holes; 

 

install the bracket on the wall and fix it. 

 
 

 

 

Fig. 8 

 
 

Содержание Plaza Ext Series

Страница 1: ...peration Manual Warranty Card Household electrical convection heater Plaza Ext series 1000 BEP EXT 1500 BEP EXT 2000 Prior to operation read carefully this Manual and keep it in a safe accessible plac...

Страница 2: ...specified on the nameplate is based on the tests under certain load 6 The manufacturer retains the right to modify the structure delivery set or manufacturing technology of the product for the improv...

Страница 3: ...t Immediately take the plug out of the socket Never operate the heater with damaged cable plug in case of faults falls or other damages Contact a skilled electrician to check electrical mechanical adj...

Страница 4: ...r to avoid overheating The protective screen does not provide full protection of children and handicapped persons To avoid accidents damaged power cable should be replaced by a qualified electrician T...

Страница 5: ...Off button 2 Full half power 3 Control buttons 4 Control buttons 5 Switch off timer 6 Anti freeze device Remote control Fig 4 1 Power On Off button 2 Full half power 3 Control buttons 4 Control button...

Страница 6: ...eater to a socket with other high power electrical appliances connected Switching the device ON Plug the Timer into this socket First press the power button to turn the device on at the switched off t...

Страница 7: ...be the temperature set point Parent control buttons lock During operation press simultaneously the buttons or and hold them pressed for more than 3 s to lock the system The indicator will be lit on t...

Страница 8: ...ower or the swimming pool If the power cable is damaged contact a qualified electrician or a service person NEVER cover the working heater Before storage arrangements ensure the heater is cool If the...

Страница 9: ...upside down take one of the stands with the rollers apply the plate of the stand to the place of fixing on the convector so that the convex part of the plate tightly joined the convector case the scre...

Страница 10: ...l address building 12 4 Sharikopodshipnikovskaya str Moscow 115088 Russian Federation Phone 8 495 786 69 69 Complies with the requirements of regulatory documents GOST R 52161 2 30 2007 GOST R 51318 1...

Страница 11: ...er is entitled to apply to the Seller The liability for the device misfunctioning by the fault of the installation mounting company is laid on the latter In such a case apply to the installation mount...

Страница 12: ...the product during warranty or paid for repair or purchased separately from the product is three months from the date the Buyer received the repaired product or sale to the latter of such parts This W...

Страница 13: ...s use of corrosion active water corrosion from electrical chemical reaction untimely technical maintenance of the water heating units according to the Operation Manual including non observance of the...

Страница 14: ...in the system diagnosis of all the electronic components of the air conditioner cleaning of the drain system This procedure will prevent faults and provide reliable performance of your air conditioner...

Страница 15: ...____________ Installer s address _________________________ ________________________________________ Installer s phone __________________________ ________________________________________ Installer s si...

Страница 16: ...www ballu ru...

Отзывы: