Operation 7
display, the time indicator flashes (the timer is set by
the clock). Press the buttons
or
to increase
or decrease the time by one hour; the timer can be set
for the period 0-24 hours. When holding the buttons
or
pressed the operation time will be
increased or decreased by 1 hour per 0.5 s. The factory
setting - 0 hours. When the indicator is on, the system
starts to count time according to the previous setting
unless a new value is set within 5 s. Every time when
the buttons
or
are pressed the system
starts new count of time or returns to the initial
parameters after the timer finishes operation, then
turns off and ends operation. To cancel the timer
operation press again the... button
Switching the device OFF
To switch the device off press the power... button
in any mode of operation.
Auto Restart RESUME function
It enables to automatically switch the device on at an
unscheduled power cutoff with all the settings active
by the moment of power cutoff stored when the power
is resumed. The additional Resume function stores the
set temperature. Press the power button to turn the
device on after it is off or timer switch off: the last set
temperature will be the temperature set point.
Parent control (buttons lock)
During operation press simultaneously the buttons
or
and hold them pressed for more than 3
s to lock the system. The indicator... will be lit on the
front panel.
To unlock: holding pressed the
buttons
or
for more than 3 s.
Power saving mode
This mode enables to select power
of heating. Full power mode is set by default. Press the
power selector button
to set the heating power.
The heater will operate at maximal power. The
indicator... will be lit on the front panel of the convector
. Press the
button again, and half power of
the heater will be activated. When setting half power
the
indicator will be lit on the front panel of the
convector.
Overheat protection function
The device is equipped with the automatic switch which
is activated when the upper temperature limit is
reached. In case of overheating the heater is
automatically switched off.
Care and maintenance
Regular cleaning of the device at continuous operation
Prior to cleaning disconnect the heater from the mains.
Prior to cleaning ensure the heater has cooled down.
Use wet cloth (not soaking) to clean dust and dirt from
the external part of the heater.
Use vacuum cleaner to remove dust and lint from the
heat dissipation grills. Prior to connecting the heater to
the mains ensure it is dry.
Cleaning of the rear panel of the wall-mounted heater
Fig. 6