Safety instructions
Read the instructions carefully
before operating. Familiarize
yourself with the device and
methods of controlling the heat
generator.
Follow
the
maintenance
instructions and the fault table
described in this manual.
Do not block the inlet and outlet
of the heat generator.
Do not use gas heat generators
in basements or other rooms
below ground level.
In a room where a gas heat
generator is operating, constant
ventilation must be provided in
accordance with the technical
specifications.
NOTE:
A sufficient level of ventilation
corresponds to two changes of
air per hour.
Minimum dimensions of the
room and the area of the
ventilation holes are shown in
the table:
Parameter /
Model
BHG-
10
BHG-
10M
BHG-
20
BHG-
20M
BHG-
40
BHG-
60
BHG-
85
Minimum area
of ventilation
openings, cm
2
250
425
825
1325
1875
The minimum
room volume, m
3
100
170
330
530
750
• The size of the room should not
be less than specified in the
technical specifications.
• The gas heat generator should
not be used in the immediate
vicinity of explosive substances.
• Do not direct warm air from the
heat generator to gas cylinders,
even if the cylinder is frozen.
• The installation, transportation
and storage of gas cylinders
should be in accordance with
the rules, regulations and
instructions for safe operation
adopted in your region.
• Check that the product is
properly grounded.
• When disconnecting the heat
generator from the mains, do
not pull on the power cord.
• Repair
of
worn-out
and
damaged power cords, as well
as plugs, should only be carried
out by a qualified authorized
Safety instructions