10
Technical specifications
Technical specifications
Parameter / Model
BHG-10М
BHG-20М
BHG-10
BHG-20
BHG-40
BHG-60
BHG-85
Maximum heat output, kW
10
17
10
17
33
53
75
Rated power consumption, W
32
32
32
32
53
103
220
Rated current, А
0.15
0.15
0.15
0.15
0.24
0.48
1
Gas pressure, bar / Mpa
1.5/0.15
1.5/0.15
1.5/0.15
1.5/0.15
1.5/0.15
1.5/0.15
1.5/0.15
Fuel consumption, kg / h
0.7-0.8
1.3-1.45
0.7-0.8
1.3-1.45
2.5-2.7
4.0-4.4
5.6-6.2
Supply voltage, V/Hz
230~50
230~50
230~50
230~50
230~50
230~50
230~50
Air productivity, m
3
/ h
270
270
270
270
720
1000
2000
Volume of the heated room, m
3
300
400
300
400
700
1000
1600
Fuel
Propane, propane-butane, butane
Appliance category
I
3P
, I
3B/P
Nozzle diameter, mm
0.6
0.85
0.6
0.85
1.25
1.75
2.0
Degree of protection
IP10
IP10
IP10
IP10
IP10
IP10
IP10
Electrical protection class
I class
I class
I class
I class
I class
I class
I class
Hose type / Hose length
EN16436 (connecting dimensions: G1/4RH and G3/8LH) / 2 m.
Country designation
АМ, АТ, ВE, BY, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HU,
IE, IS, IT, KZ, KG, LT, LV, LU, PL, PT, NO, RO, RU, SE, SI, SK, BG
Net weight, kg
4.3
4.3
5.3
5.4
8.3
11.7
14.1
Gross weight, kg
5.4
5.4
5.9
6
9.1
12.5
15
Appliance dimension, mm
(W x H x D)
190х285х460 190х285х460 190х290х445 190х290х445 220х335х595 270х415х710 270х415х810
Packing dimensions, mm
(W x H x D)
220x270х478 220x270х478 220x270x478 220x270x478 245x310х615 300х390x740 300х390x840
Check gas tightness
Check the tightness of the gas hose and all con-
nections in the gas supply line. Propane has a
characteristic odor, which makes it easy and
timely to detect a leak. If you find a leak, you must
isolate the open fire and close the gas cylinder
valve. Do not check for leaks using open flames.
Detect leaks only by smell. In order to confirm the
presence of a leak, lather the intended leakage lo-
cation with soap suds. Seal all threaded connec-
tions in the gas supply line using special Loctite
577 sealer.
Scheme 2
For BHG-10, BHG-20, BHG-10M, BHG-20M
Elektroda
Termo
č
l
á
nek
5 mm
4,5 mm
the burner head from the combustion chamber.
Clean the burner head with compressed air.
Replace parts with signs of wear and cracks.
Check electrode and thermocouple settings in
Schemes 1 and 2.
Содержание BHG-10
Страница 38: ...Dovozce...