16
2.3.7
Three phase connection to package size C
Location
Connector X1, single or 2-part connector
Part number
MD
2
A...
Input voltage
230VAC, 3
φ
line to line
Range
220-250VAC
Note:
Tightening torque for terminal block connections is 4.4~5.3 lbin (0.5~0.6Nm).
The threaded holes in the top and bottom of the enclosure are for cable clamps (provided).
The holes are threaded for M4 bolts no longer than 0.47” (12mm) in length. Longer bolts
may short circuit the electrical components inside the MintDrive.
2.3.8
24V control supply
Depending on model, a 24VDC control supply may be required to provide power to the control
electronics when power is removed from the amplifier (see page 2). This is useful for safety where
power needs to be removed from the amplifier stage but the control electronics must be powered to
retain position and I/O information. The 24VDC supply is connected via X1.
Note:
A 24VDC supply is always required for the drive enable input on connector X13.
Location
Connector X1, single or 2-part connector
Part number
MD
xxxxxx-xxx
3
Input voltage
24V
Input current
1.6A (maximum)
Range
20.4 - 28.8VDC
Note:
Tightening torque for terminal block connections is 4.4~5.3 lbin (0.5~0.6Nm)
L1
L2
E
L3
or
Earth stud
+24V
GND
Содержание MintDrive
Страница 2: ...MN1274 06 2001 Installation Manual Installation Manual...
Страница 3: ......
Страница 13: ...xii...
Страница 56: ...43 Figure 22 Auxiliary encoder circuit...
Страница 91: ...78...
Страница 97: ...84...
Страница 109: ...96...
Страница 111: ...98 Figure A 1 MintDrive Closed Loop System Motor Speed Filter 16 Sample Filter...
Страница 119: ...106...
Страница 141: ...128...
Страница 147: ...134...
Страница 154: ......