47
3.4.6
Connecting Baldor HMI Operator Panels
Baldor HMI Operator Panels use a 15-pin male D-type connector (marked PLC PORT), but the
MintDrive connector X7 is a 9-pin D-type connector. If you do not require hardware handshaking then
the following connections should be made:
7 RTS
8 CTS
3 TXD
2 RXD
5 GND
1
RXD 2
TXD 3
GND 5
Baldor HMI
PLC PORT
MintDrive
X7
Figure 25 - Cable wiring if hardware handshaking is
not
required
If hardware handshaking is required then the following connections should be made:
7 RTS
8 CTS
3 TXD
2 RXD
5 GND
1
RXD 2
TXD 3
GND 5
Baldor HMI
PLC PORT
MintDrive
X7
CTS 11
RTS 10
Figure 26 - Cable wiring if hardware handshaking
is
required
Содержание MintDrive
Страница 2: ...MN1274 06 2001 Installation Manual Installation Manual...
Страница 3: ......
Страница 13: ...xii...
Страница 56: ...43 Figure 22 Auxiliary encoder circuit...
Страница 91: ...78...
Страница 97: ...84...
Страница 109: ...96...
Страница 111: ...98 Figure A 1 MintDrive Closed Loop System Motor Speed Filter 16 Sample Filter...
Страница 119: ...106...
Страница 141: ...128...
Страница 147: ...134...
Страница 154: ......