METER OVERVIEW
The Electronic Preset Meter RF2 (EPM RF2) is equipped with RF (radio frequency)
communications to communicate with a fluid management system keypad to get authoriza
-
tion and dispense information. This is referred to in the manual as the RF2 Mode.
The meter can also be run as a standard EPM. This is referred to in the manual as the EPM
Mode. This is intended for start-up purposes or when the fluid management system is not in
use.
Once a work order has been entered at the keypad, the operator simply pushes the
button on the meter to start communications between the meter and the keypad. The meter
receives authorization from the keypad to unlock and the dispense batch quantity. When
the trigger is pulled the pre-set dispense batch quantity dispenses.
The meter automatically shuts off when the dispense batch quantity has been reached.
A “Top Off” feature allows additional fluid to be dispensed and tracked after the batch quan
-
tity has been dispensed.
Upon completion of the dispense, the operator presses the button. The meter then
locks, prohibiting any unauthorized dispense of fluid and the dispense quantity is sent to
the keypad.
Meter Buttons
Used to enter the dispense Batch quantity when in the
EPM Mode. These buttons are
NOT
used in RF2 mode.
Total
Used to display the accumulated total of fluid dis
-
pensed, as well as the re-settable total.
Auto
Used to enter and exit the manual or batch mode when
in EPM mode. This button is
NOT
used in RF2 mode.
Meter Display
Reset
Used to initiate RF2 communications from the meter to the Keypad.
•
Used in EPM mode to clear the previous batch.
•
Used to reset the re-settable total dispensed while pressing the TOTAL button.
•
Shut-Off or Stop
Used to stop the flow through an Emergency Override.
1