OPERATING MODE FUNCTIONS
These functions operate the same in RF2 Mode and EPM Mode.
Re-settable/Accumulated Totals
The meter has two flow totalizers. One is Re-settable Total the other is Accumulated Total.
1. To see the Accumulated Total and the Re-settable Total:
• Press and hold the button to see the Accumulated Total.
• Continue holding the button.
• After three seconds the screen changes to the Re-settable Total.
2. Resettotal displays the total fluid dispensed since
the Resettable Total was last set back to zero.
3. Press the button while viewing Resettotal to
set it back to zero.
4. Release the button to return to the operating
display.
Re-settable Total
NOTE:
The Accumulated Total cannot be reset unless the user changes from English units
to metric units or from metric to English units.
(See the
Change Factory Settings,
Change Unit of Measure
section of this manual).
Emergency Override
In case of an emergency or to interrupt a batch, the meter is equipped with an Emergency
Override.
1. Press the red button to activate the Emergency Override. The override closes the
valve, immediately stopping fluid flow.
2. Batching can continue after an Emergency Override by pulling up on the trigger.