10
(5) Light
Press “Light” to operate the spa light. And off after 4 hours.
(6) Time set
When SPA gets through with electricity for the first time,” SET TIME" will be shown on control panel. Press "time"
first, then "Mode/Prog" later, press "Warm" or "Cool", when pressing "Warm" or "Cool", time set will be added or
deducted by 1 minute finally, press "time" again to make sure you have set time.
(7) Mode
1) Mode is changed by pressing “Warm” or “Cool”, then pressing “Mode” for change.
2) Standard Mode maintains set temperature, and it will be displayed momentarily when you switch into Standard
Mode.
3) Economy Mode heats the spa to the set temperature only during filter cycles. Eco will display when water temp
is not current, and will alternate with water temp when the pump is running.
Sleep Mode heats the spa to within 20
℉
/ 10
℃
of the set temperature only during filter cycles. "SLP" will display
when water temp is not current, and will alternate with water temp when the pump is running.
(8) Preset Filter Cycles
The first preset filter cycle begins 6 minutes after the spa is energized. The second preset filter cycle begins 12
hours later. Filter duration is programmable for 2, 4, 6, or 8 hours or for continuous filtration (indicated by FILC).
The default filter time is 2 hours.
To program, Press “Warm” or “Cool”, “then", “Jets 1”. Press “Warm” or “Cool" to adjust. Press “Jets l" to exit
programming.
The first presetting filter cycle starts from 8AM and ends at 10AM.the second starts from 8PM and end at 10PM.
For circulation systems, the circ pump and the ozone generator (if installed) run 24 hours. In hot environments, the
circ Pump may turn off for 30 minute periods, except during filter cycles. At the beginning of each filter cycle all
other equipments will run briefly to pure the plumbing.
(9) Additional set for filter cycle
Basically you do not need to set the filter cycle, but if you want, press “Time”“ Model/Prog” in turn in 3 seconds,
then press “Mode/Prog” again, and SET START FILTER1(AM) will show on panel. Press “Warm” or “Cool” to reset
the beginning and ending time of filter cycle.
When pressing “Mode/Prog”, you will see “SET START FILTER1”then press ”Warm” or ”Cool” to make the
adjustment.
When pressing “Mode/Prog” you can see “SET START FILTER2(PM)”then press “Warm” or “Cool” to make the
adjustment.
When pressing “Mode/Prog” and you will see “SET START FILTER2”then press ”Warm” or” Cool” adjustment.
Finally, press “Mode/Prog” to make sure of the set.
(10) Panel lock and unlock
Press “Time”, lower” and ”Warm” in turn within 3 seconds to lock the panel.
Press “Time”, “Blower” and ”Cool” in turn within 2 seconds to unlock the panel.
Содержание GS523DZ
Страница 1: ...INSTALLATION DU SPA ET MODE D EMPLOI...
Страница 36: ...35 VS MAR 2020...