11
Signal Diagnosis on Display
SIGNAL
SIGNIFICATION
REQUIRED OPERATION
No signal on display, and the power
has been cut off to the spa
The control panel will be disabled until power returns. Spa
setting will be preserved until next power up.
- -
Temperature Unknown
After the pump has been running for 2 minutes, the current
water temperature will be displayed.
0HH
“Over-heated”-the Spa has shut
down.*one of the sensor has
detected 118°F/47.8
℃
at the heater
Do not enter the water. Remove the cover and cool the
water. Once the heater has cooled, reset by pushing any
button. If spa does not reset, shut off the power to the spa
and call your dealer or service organization.
0H5
“Over-heated”-Spa has shut down
.*one of the sensor has detected the
spa water is 110°F /43.5
℃
.
Do not enter the water. Remove the cover and cool the
water. At 107°F/41.7
℃
, the spa should automatically reset.
If spa does not reset, shut off the power to the spa and call
your dealer or service organization.
5nA
Spa is shut down. *The “A” Jack in the
sensor is not working.
If the problem persists, please contact your distributor or
service organization (This might temporarily appear when
over-heating).
5nb
Spa is shut down. *The “B” Jack in the
sensor is not working.
If the problem persists, please contact your distributor or
service group (This might temporarily appear when
over-heating).
5n5
Sensors are out of balance. If alter-
nating with spa temperature, it may just
be a temporary condition. If flashing by
itself, spa is shut down.
If the problem persists, please contact your distributor or
service group.
HFL
A
significant
difference
between
temperature
sensors
has
been
detected. This could indicate a flow
problem.
If the water level is normal, make sure all the pumps have
been primed. If the problem still exists, please contact your
distributor or service organization.
LF
Continuous low flowing problem.
(Display on the fifth occurrence of HFL
message within 24 hours) The heater is
shut down, but other functions on SPA
keep running.
Follow action required for “HFL” message. Heating
capability of the spa will not reset automatically; you may
press any button to reset.
dr
Possible inadequate water, poor flow,
or air bubbles is detected in the heater.
Spa is shut down for 15 minutes.
If the water level is normal, make sure all the pumps have
been primed. Press any key to reset. This message will be
reset within 15 minutes. If the problem still exists, please
contact your distributor or service organization.
dry
Inadequate water detected in heater.
(The third time for “dr” signal.)Spa is
shut down.*
Follow action required for “dry” message. SPA will not be
reset automatically, press any key to reset it manually.