- 4 -

Filtration

The system is factory-programmed with one filter cycle that will run in the evening (assuming the time-of-

day is properly set) when energy rates are

often lower. The filter time and duration are programmable. Refer to the TP600 User Guide (40940) for

detailed instructions.

A second filter cycle can be enabled as needed.

Dual Temperature Ranges

This system incorporates two temperature range settings with independent set temperatures. The

High

Range

is indicated in the display

and might be set between 80

°

F and 104

°

F. The

Low Range

is

indicated in the display

and might be set between 50

°

F and 99

°

F. Low Range may be

economical during non-use periods. More specific temperature ranges, such as 50

°

F to 79

°

F for low

range, or 90

°

F to 104

°

F for High Range, may determined by the manufacturer.

Ready and Rest Modes

If the filtration pump is a 2-Speed Pump 1,

Mode will circulate water every 1/2 hour, using Pump 1

Low, in order to maintain a constant water temperature, heat as needed, and refresh the temperature display.

This is known as

polling.

Mode will only allow heating during programmed filter cycles. Since

polling does not occur, the temperature display may not show a current temperature until the filtration pump

has been running for a minute or two.

Mode may appear when Jets 1 is activated.

Complete Reference

Download the complete User Interface and Programming Guide at

http://service.balboa-

instruments.com/zz40940_download.zip

User Interface and Programming Reference – Standard Menus

System Model: BP-Series Systems are BP5XX, BP6XX, BP1XXX, BP2XXX.

Software Version: 7.0 and later

Panel Model: TP600 Series TP400 Series

Software Version: 2.3 or later 2.4 or later

1. First Start-up

Navigating the entire menu structure is done with 2 or 3 buttons on the control panel.Some panels have separate

WARM (Up) and COOL (Down) buttons, while others have a single Temperature button. In the navigation

diagramsTemperature buttons are indicated by a single button icon.
Panels that have two Temperature buttons (Warm and Cool) can use both of them to simplify navigation and

programming where a single Temperature icon is shown.The LIGHT Button is also used to choose the various

menus and navigate each section.Typical use of the Temperature button(s) allows changing the Set

Temperature while the numbers are flashing in the LCD.Pressing the LIGHT button while the numbers are

flashing will enter the menus.The menus can be exited with certain button presses. Simply waiting for several

seconds will return the panel operation to normal.

Power-up Screens

Each time the System powers up,
a series of numbers is displayed.

****

Main Screen

While the Temperature is

still flashing, press Light.

Содержание BP6013G1

Страница 1: ...EN SPAS Installation and Directions of Use...

Страница 2: ...II Troubleshooting page37 IX Warranty process page38 FR SAV INFORMATION VIDEO CONTACT EN AFTER SALES SERVICE INFORMATION VIDEO CONTACT DE REPARATUR SERVICE UND ERSATZTEILE INFORMATIONEN VIDEO KONTAKT...

Страница 3: ...stem and water 1cm over all the jets when installed Balboa system 20 No water or water level doesn t reach the probe screw or over all the jets do not operate the spa 21 If the spa not to use please k...

Страница 4: ...red to as Temperature Buttons Some panels only have a single Temperature Button Press a Temperature Button once and the current Set Temperature will begin to flash on the LCD The Set Temperature and t...

Страница 5: ...ration pump has been running for a minute or two Mode may appear when Jets 1 is activated Complete Reference Download the complete User Interface and Programming Guide at http service balboa instrumen...

Страница 6: ...can manually exit the priming mode after the pump s have primed Regardless of whether the priming mode ends automatically or you manually exit the priming mode the system will automatically return to...

Страница 7: ...w This is because the system requires approximately 1 minute of water flowing through the heater to determine the water temperature and display it or M019 is a Message Code See Page 2 SPA Behaviour Pu...

Страница 8: ...ause the temperature to flash Pressing a temperature button again will adjust the set temperature in the direction indicated on the button When the LCD stops flashing the spa will heat to the new set...

Страница 9: ...s polling REST Mode will only allow heating during programmed filter cycles Since polling does not occur the temperature display may not show a current temperature until the heater pump has been runni...

Страница 10: ...temperature is reached or 1 hour has passed After 1 hour the System will revert to Rest Mode This mode can also be reset by entering the Mode Menu and changing the Mode 5 Show and Set Time of Day Be...

Страница 11: ...set but since the spa started at noon the filter cycles will run as programmed Flip Invert Display Note Some panels may have a dedicated FLIP button which allows the user to flip the display with a s...

Страница 12: ...ton the ONLY button that will work in the Unlock Sequence is the UP button Hold Standby Hold Mode M037 Hold Mode is used to disable the pumps during service functions like cleaning or replacing the fi...

Страница 13: ...set using a start time and a duration Start time is indicated by A or P in the bottom right corner of the display Duration has no A or P indication Each seting can be adjusted in 1 hour increments The...

Страница 14: ...Pumps and or a Blower will purge water from their respective plumbing by running briefly at the beginning of each filter cycle If Filter Cycles 1 is set for 24 hours enabling Filter Cycle 2 will init...

Страница 15: ...12 hr and 24 hr display RE MIN DERS Reminders Turn the reminder messages like Clean Filter On or Off CLN UP Cleanup Cleanup Cycle Duration is not always enabled so it may not appear When it is availa...

Страница 16: ...s 10 Utilities and Information INFO System Information sub menu The System Information Menu displays various settings and identification of the particular system As each item in the menu is highlighte...

Страница 17: ...ities In addition to INFO The Utilities Menu contains the following GFCI GFCI Test Feature not available on CE rated systems GFCI Test is not always enabled so it may not appear This screen allows the...

Страница 18: ...17 Utilities...

Страница 19: ...t be shut off until a service person can correct the problem Forcing the GFCI Trip Test The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu The GFCI should...

Страница 20: ...n a regular basis Utilities Fault Log A Little History can tell a lot The Fault Log stores up to 24 events in memory and they can be reviewed under the Fault Log Menu Each event captures a Fault Messa...

Страница 21: ...on has been detected or the Aux Freeze Switch has closed and all pumps and blower are activated All pumps and blower are ON for at least 4 minutes after the potential freeze condition has ended or whe...

Страница 22: ...ted Checks below Heater is Dry M027 There is not enough water in the heater to start it The spa is shut down After the problem has been resolved you must press any button to reset and restart heater s...

Страница 23: ...22 12 Sensor Related Messages 13 Miscellaneous Messages This message can be reset from the topside panel with any button press...

Страница 24: ...23 14 System Related Messages This message can be reset from the topside panel with any button press...

Страница 25: ...set a displayed reminder message The Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD is an important safety device and must be tested on a regular basis to verify its reliability...

Страница 26: ...ing means to be provided at time of installation Permanently connected Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter GFCI or Residual Current Device RCD mounted at...

Страница 27: ...ons Warning The equipment and controls shall be located not less than 1 5 meters horizontally from the spa or hot tub Warning GFCI or RCD Protection The Owner should test and reset the GFCI or RCD on...

Страница 28: ...27...

Страница 29: ...ton press is indicated Ignore the direction reversal paragraph 3 JETS 1 operation with circ pump Press JETS once to turn circ pump on and press the button again to turn massage pump surfing pump on Ci...

Страница 30: ...noff See your dealer for details 3 Diagnostic Messages Message Meaning Action Required No message on display The control panel will be disabled until power returns Spa settings will be preserved until...

Страница 31: ...Press any button to reset Brief Introduction of All SPA Models 1 Materials Spa models are made of acrylic plate with fiber glass reinforced Color of Acrylic A010 White cloud A020 Pearl black WT6064 w...

Страница 32: ...romatic perfume etc Description on Using Parts A MANUAL OF THE WATERPROOF BLUETOOTH AMPLIFIER SYSTEM Configuration 1 Waterproof speakers 2pcs 30 50W 2 Bluetooth amplifier 1pc Equipment parameters 1 Po...

Страница 33: ...filters daily maintenance Type one 1 Remove the outer cover of the skimmer 2 Pull out the skimmer screw 3 Take out the paper core 4 Wash the paper core with water reset it after cleaning and dry out...

Страница 34: ...ne and tear out the package of the paper core and put it inside the filtration bucket 6 Match the paper core correctly inside and screw it down in sequence then put the cover of filtration bucket on t...

Страница 35: ...W 56827 02 Titanium 3kW Custom Box Overlay Box Overlay Part Number N A CE System Model For 3 0kW BP21 BP6013G2 RCA3 0K Software Version ID M100_226 V37 0 Software Version 37 0 File Name BP6013_37 0_BP...

Страница 36: ...35 Diagram of 220V 230V L N E Diagram of 380V L N E 2 control system GS100 GS500 Panels VL260D panel Electric box GS500Z...

Страница 37: ...h acetone solution ammonia water and organic solvent otherwise it may possibly damage the surface of the bathtub Mildly wipe off the adhesive stains on the bathtub with soft fabric and gasoline 2 If t...

Страница 38: ...ide plate of the bathtub 3 Replace the thermostat cut off power supply open the bathtub side plate turn off the valves on both ends of thermostat remove the wires loosen the fixed bolts and take out t...

Страница 39: ...a control system SPA control system is found to be defective in the field the RMA can be handled either through the OEM or through one of Balboa offices In all cases the OEM dealer distributor is enco...

Отзывы: