![Balboa BP6013G1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/balboa/bp6013g1/bp6013g1_installation-and-directions-of-use_3577904019.webp)
- 18 -
Utilities
–
GFCI Test Feature
Not Available on CE Rated Systems.
A GFCI is an important safety device and is required equipment on a hot tub installation.
Your spa may be equipped with a GFCI Protection feature. (UL rated systems only.) If your spa has this feature
enabled by the manufacturer, the GFCI Trip Test must occur to allow proper spa function.
Within 1 to 7 days after startup, the spa will trip the GFCI to test it. (The number of days is factory programmed.)
The GFCI must be reset once it has tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will
indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person
can correct the problem.
Forcing the GFCI Trip Test
The installer can cause the GFCI Trip Test to occur sooner by initiating it using the above menu.
The GFCI should trip within several seconds and the spa should shut down. If it does not, shut down the power and
manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly. Verify the function of
the GFCI with its own test button. Restore power to the spa and repeat the GFCI Trip Test.
Once the GFCI is tripped by the test, reset the GFCI and the spa will operate normally from that point. You can verify
a successful test by navigating to the above menu. PASS should appear after a temp button is pressed from the GFCI
screen.
The end-user must be trained to expect this one-time test to occur and how to properly
reset the GFCI.
Содержание BP6013G1
Страница 1: ...EN SPAS Installation and Directions of Use...
Страница 18: ...17 Utilities...
Страница 24: ...23 14 System Related Messages This message can be reset from the topside panel with any button press...
Страница 28: ...27...