- 3 -
Ⅱ、
Control system usage instructions
(II-1)
、
BP6013G1/G2/G3 Balboa Control System
(
TP600 /TP400 control panel)
TP600 control panel
TP400 control panel
TP400/600 Quick Reference Card
Start Up
When the GFCI for the spa is switched on to supply power, a startup sequence of numbers will appear on
the display. If no button is pressed, LINK will appear after the startup sequence. Press any button to link the
panel with the system.
The spa will enter Priming Mode. After Linking, press the
Jets Button(s)
to turn the pumps on
and off to verify that all air is purged from the plumbing, particularly the plumbing associated with the
heater. If the spa uses a circulation pump, the
Light
Button turns the Circ Pump on an off during
Priming Mode. Priming Mode will end automatically in 4 minutes. Pressing a
Temperature Button
will
exit Priming Mode manually. When Priming Mode ends, Pump 1 low will start, if no circ pump is present,
however the water temperature will not appear for a minute or so. Once the water
temperature is recognized by the system, and if it is below the
Set Temperature
,
the heater will start.
Basic Operation
The
Up
and
Down
buttons are often referred to as
Temperature Buttons
. Some panels only
have a single Temperature Button.
Press a
Temperature Button
once and the current
Set Temperature
will begin to flash on the LCD. (The
Set Temperature and the actual water temperature are often different.) While the numbers are flashing, press
a Temperature Button again to change the Set Temperature. Press-and-hold for faster adjustment. After the
new Set Temperature stops flashing, in about 10 seconds, the actual temperature is displayed again and the
new Set Tem-perature is programmed. The spa will now heat to the new Set Temperature as needed.
The
Light
Button turns the Spa Light on and off and is also used in conjunctions with the
Temperature Button(s) to navigate the system menus.
Programming
Refer to the TP600 User Guide (40940) for detailed operation, programming and message instructions.
Navigating the deeper menu structure is done with only 2 or 3 buttons on the control panel.
Pressing the Light button while the Set Temperature is flashing will enter the menus.
Pressing Light after that will proceed through the menu choices. Pressing a Temperature Button while any
menu item is showing will either edit it directly or begin an editing sequence.
Depending on the screen displayed, waiting between 10 and 30 seconds will allow the panel to return to
normal operation and a display of spa status.