- 25 -
(16) Reminder Messages Continued
(17) Warning! Qualified Technician Required for Service and Installation
Basic Installation and
Configuration Guidelines
Use minimum 6AWG copper conductors only.
Torque field connections between 21 and 23 in lbs.
Readily accessible disconnecting means to be provided at time of installation.
Permanently connected.
Connect only to a circuit protected by a Class A Ground Fault Circuit Interrupter (GFCI) or Residual Current
Device (RCD) mounted at least 5
’
(1.52M) from the inside walls of the spa/hot tub and in line of sight from
the equipment compartment.
CSA enclosure: Type 2
Refer to Wiring Diagram inside the cover of the control enclosure.
Refer to Installation and Safety Instructions provided by the spa manufacturer.