Motor will not turn over, no
lights on the
Electric
control
panel will light, and no other
functions operate.
12VDC is not being supplied to any of the system
components.
Check the battery cables and ensure they are clean and
tight. Ensure that the batteries are properly charged and
capable of supplying the required power.
Engine shuts down
randomly, and requires the
key to be turned off and
back on before restart.
The fuel shut off solenoid or associated wiring may be
damaged or defective.
Check the wiring to the fuel shut off solenoid for loose
connections or breaks.
Replace the fuel shut off solenoid.
Refer to the Diesel Engine Operators Manual for more
trouble-shooting tips information.
Debarker will not activate.
Open electrical panel on dust chute side of head carriage
and check 15 amp fuse, debarker wires on terminal strip and
debarker solenoids to see if they are energized.
12VDC is not being supplied to the debarker, the debarker
control solenoid, or the solenoid control circuitry.
Please refer to the Control Schematics section and Panel
Layout section for more information.
Debarker locks up when it is
into the material.
Debarker is being forced into the material to hard.
Check the pressure.
Guide arm will not move in
either direction.
12VDC is not being supplied to the guide arm solenoid or
the guide arm switch is defective.
Please refer to the Control Schematics section and Panel
Layout section for more information.
While holding one multimeter lead on the GA+ terminal and
the other on the GA- terminal move the guide arm switch to
the left and right. If there is +12VDC and -12VDC as the
switch is moved, check the wiring from the terminal to the
guide arm for loose or broken connection.
Ensure solenoids are energizing.