Baker Blue Streak Portable or Stationary Band Sawmill - Rev 2, 03/07;
WWW.BAKER-ONLINE.COM
67
or bottom of the coils if they are not energized they will be
loose on the piston. If one of the coils is energized then refer
to the electrical part of this manual for further information. If
not continue to next step.
3. Check the hoses at the motor for flex when the valve is
pulled for up motion.
If the hoses are flexing at the motor and the pressure is
minimal at the operator station then check the pressure at
the manifold station located on the left side of the saw head.
If the pressure is low then the main pressure may need to be
adjusted. The valve may be adjusted with a 5/32 Allen
wrench and a 9/16 wrench by turning the adjuster screw
clock wise will increase the pressure.
4. Check the offset if set works are applicable on your system
to see if the offset will raise the saw head.
If the off set will raise the head the problem may be in the
manual valve. To check the valve shut off the engine or
power before continuing. On the manual valve remove the
cap on the back side of the valve with a 3/16 Allen wrench
and clean the spring and cup replace the cap and try the
function again. If this didn’t fix the problem contact our
service department immediately.
If your system does not have set works the manual valve
procedure is the same.
Nothing moves
hydraulically and gauge
at the control station
shows no pressure.
Either the hydraulic pump or the main system pressure valve is
defective.
For
diesel
models, swap the front and rear main system
pressure valves. If the problem is corrected the original valve
is defective. If the problem remains, the hydraulic pump is
defective.
For
electrical
models, if the gauge on the hydraulic unit shows
pressure, but the gauge at the control station does not, the
main system pressure valve is defective. If the gauge on the
stand-alone unit shows no pressure the problem is in the pump
assembly.