background image

14  |  Baker Hughes

Copyright 2022 Baker Hughes Company. All rights reserved.

Type 27 Restrictor Assembly

The Type 27 Restrictor Assembly includes the adjustable orifice 

and an integrated check valve to protect the diaphragm from 

damage in case of a sudden spike in back pressure to the 

system.

Figure 23

 - Type 27 Restrictor Assembly

The Type 27 Restrictor is connected to the main body of the 

Series 22 pilot by two socket head cap screws and two pressure 

retaining pins.

Figure 24

 - Series 22 Pilot Assembly

Care should be taken to avoid damaging the pin O-Rings during 

assembly.
The variable orifice can only be removed from the Restrictor 

block after separation from the Series 22 block.

Figure 25

 - Restrictor Block Assembly 

The check valve can be removed from the Restrictor block while 

attached to the Series 22 block. Care should be taken to assure 

that the check valve is installed in the proper orientation as it is 

easily reversed due to its universal nature. Flow should be from 

the bottom (Cap side) to the Loading port.
The Type 27 Restrictor block has multiple options for control line 

mounting.

Figure 26

  - Restrictor Block

The standard option is to plug ports A and B. The ½” NPT Sense 

port is connected to the Upper Actuator housing connection 

(Sense Connection) on the FlowMax НР. The Loading port is 

connected to the Lower Actuator housing connection on the 

FlowMax НР.

Other control options are available. Please contact your Mooney 

Representative for additional information.

Flow

Содержание Mooney 22 Series

Страница 1: ...Mooney 22 22H Series Pilots Instruction Manual Rev A Baker Hughes Data Classification Public...

Страница 2: ...LAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET...

Страница 3: ...Table of Contents Product Description 4 General Description 5 Pilot Markings Figure 3 7 Series 22 Pilot Piping Schematics Loading Type Valves 8 Series 22 Pilot Loading Type Valve Installation 9 Maint...

Страница 4: ...ax HP actuator in gas applications Series 22 Stainless steel construction with a 3 to 450 psig 0 2 barg 31 barg control pressure range Series 22H High pressure stainless steel construction with a 200...

Страница 5: ...lnlet and Loading Ports 3 The INLET port is where upstream supply pressure is connected to the Series 22 Pilot Assembly The LOADING port is used to connect the controlling signal from the pilot to th...

Страница 6: ...0 F 29 C to 66 C Emergency 40 F to 200 F 40 C to 93 C Maximum Inlet Pressure 1500 psig 100 barg Maximum Loading Pressure 1500 psig 100 barg Maximum Outlet Pressure 1500 psig 100 barg Maximum Emergency...

Страница 7: ...5 Nameplate for Series 22 Pilots Figure 6 Spring Range Nameplate for Series 22H Pilots Table 4 Item Definition Mooney Pilot Trademarked name of pilot Series Model number of pilot Control Pressure The...

Страница 8: ...tubing from filter OUTLET connection to the Series 22 pilot INLET port 2 Type 30 filter mounted in inlet piping 3 LOADING port of Series 22 pilot connected to Loading connection on the actuator housi...

Страница 9: ...l sales representative for ordering information 1 PERSONNEL Installation of the Series 22 Pilot on the FlowMax Valve or any other manufacturer valve should be made by qualified personnel familiar with...

Страница 10: ...fely release pressure and process fluid from the regulator body and pilot system Failure to properly complete these steps may result in personal injury and property damage 1 After depressurizing the p...

Страница 11: ...t Body 4 Install Spring Housing Cap Screws Use cap screws supplied and tighten evenly to 8 ft lbs 10 8 Nm torque 5 Install Spring and Spring Follower Lubricate Spring Follower with a Petroleum Grease...

Страница 12: ...bricate both Body Insert O Rings with Parker Super O Lube or equivalent Petroleum based Lubricant and install on Body Insert Cartridge 9 Body Insert Assembly Lift Bottom Cap complete with valve mechan...

Страница 13: ...20 HP Diaphragm Assembly NOTE Over tightening will distort the Pilot Diaphragm 2 Place Diaphragm Assembly in the pilot body with the diaphragm touching the grooved sealing surface of the pilot body a...

Страница 14: ...block after separation from the Series 22 block Figure 25 Restrictor Block Assembly The check valve can be removed from the Restrictor block while attached to the Series 22 block Care should be taken...

Страница 15: ...Mooney 22 22H Pilots Instruction Manual 15 Copyright 2022 Baker Hughes Company All rights reserved Notes...

Страница 16: ...com Copyright 2022 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation as t...

Отзывы: