background image

Tech Field Support & Warranty:

Phone: +1-866-827-5378

[email protected]

Direct Sales Office Locations

Australia

Brisbane

Phone:   +61-7-3001-4319
Perth

Phone:   +61-8-6595-7018
Melbourne

Phone:   +61-3-8807-6002

Brazil

Phone:  +55-19-2104-6900

China

Phone:  +86-10-8400-7888

France

Courbevoie

Phone:  +33-1-4904-9000

India

Mumbai

Phone:  +91-22-8354790

New Delhi

Phone:  +91-11-2-6164175

Italy

Phone:  +39-081-7892-111

Japan

Tokyo 

Phone:  +81-03-6871-9008

Korea

Phone:  +82-31-620-1736

Malaysia

Phone:  +60-3-2161-03228

Mexico

Phone:   +52-55-3640-5060

Russia

Veliky Novgorod

Phone:  +7-8162-55-7898
Moscow

Phone:  +7-495-585-1276

Saudi Arabia

Phone:  +966-3-341-0278

Singapore

Phone:  +65-6861-6100

South Africa

Phone:  +27-83-387-9300 

South & Central 

America and the Caribbean

Phone:   +55-12-2134-1201

Spain

Phone:  +34-935-877-605  

United Arab Emirates

Phone:  +971-4-8991-777

United Kingdom

Phone:  +44-7919-382-156

United States

Houston, Texas

Phone:  +1-713-966-3600

Find the nearest local Channel Partner in your area:

valves.bakerhughes.com/contact-us

valves.bakerhughes.com

Copyright 2022 Baker Hughes Company. All rights reserved. Baker Hughes provides this information on an “as 
is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy 
or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest 
extent permissible by law, including those of merchantability and fitness for a particular purpose or use. Baker 
Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special damages, claims 
for lost profits, or third party claims arising from the use of the information, whether a claim is asserted in con-
tract, tort, or otherwise. Baker Hughes reserves the right to make changes in specifications and features shown 
herein, or discontinue the product described at any time without notice or obligation. Contact your Baker Hughes 
representative for the most current information. The Baker Hughes logo,

 

Mooney, FlowMax, and Flowgrid are 

trademarks of Baker Hughes Company. Other company names and product names used in this document are 
the registered trademarks or trademarks of their respective owners.

BHMY-22-22H-Pilots-IOM-34627-0622      06/2022

bakerhughes.com

Содержание Mooney 22 Series

Страница 1: ...Mooney 22 22H Series Pilots Instruction Manual Rev A Baker Hughes Data Classification Public...

Страница 2: ...LAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET...

Страница 3: ...Table of Contents Product Description 4 General Description 5 Pilot Markings Figure 3 7 Series 22 Pilot Piping Schematics Loading Type Valves 8 Series 22 Pilot Loading Type Valve Installation 9 Maint...

Страница 4: ...ax HP actuator in gas applications Series 22 Stainless steel construction with a 3 to 450 psig 0 2 barg 31 barg control pressure range Series 22H High pressure stainless steel construction with a 200...

Страница 5: ...lnlet and Loading Ports 3 The INLET port is where upstream supply pressure is connected to the Series 22 Pilot Assembly The LOADING port is used to connect the controlling signal from the pilot to th...

Страница 6: ...0 F 29 C to 66 C Emergency 40 F to 200 F 40 C to 93 C Maximum Inlet Pressure 1500 psig 100 barg Maximum Loading Pressure 1500 psig 100 barg Maximum Outlet Pressure 1500 psig 100 barg Maximum Emergency...

Страница 7: ...5 Nameplate for Series 22 Pilots Figure 6 Spring Range Nameplate for Series 22H Pilots Table 4 Item Definition Mooney Pilot Trademarked name of pilot Series Model number of pilot Control Pressure The...

Страница 8: ...tubing from filter OUTLET connection to the Series 22 pilot INLET port 2 Type 30 filter mounted in inlet piping 3 LOADING port of Series 22 pilot connected to Loading connection on the actuator housi...

Страница 9: ...l sales representative for ordering information 1 PERSONNEL Installation of the Series 22 Pilot on the FlowMax Valve or any other manufacturer valve should be made by qualified personnel familiar with...

Страница 10: ...fely release pressure and process fluid from the regulator body and pilot system Failure to properly complete these steps may result in personal injury and property damage 1 After depressurizing the p...

Страница 11: ...t Body 4 Install Spring Housing Cap Screws Use cap screws supplied and tighten evenly to 8 ft lbs 10 8 Nm torque 5 Install Spring and Spring Follower Lubricate Spring Follower with a Petroleum Grease...

Страница 12: ...bricate both Body Insert O Rings with Parker Super O Lube or equivalent Petroleum based Lubricant and install on Body Insert Cartridge 9 Body Insert Assembly Lift Bottom Cap complete with valve mechan...

Страница 13: ...20 HP Diaphragm Assembly NOTE Over tightening will distort the Pilot Diaphragm 2 Place Diaphragm Assembly in the pilot body with the diaphragm touching the grooved sealing surface of the pilot body a...

Страница 14: ...block after separation from the Series 22 block Figure 25 Restrictor Block Assembly The check valve can be removed from the Restrictor block while attached to the Series 22 block Care should be taken...

Страница 15: ...Mooney 22 22H Pilots Instruction Manual 15 Copyright 2022 Baker Hughes Company All rights reserved Notes...

Страница 16: ...com Copyright 2022 Baker Hughes Company All rights reserved Baker Hughes provides this information on an as is basis for general information purposes Baker Hughes does not make any representation as t...

Отзывы: