background image

© 2019 Baker Hughes, a GE company, LLC. All rights reserved.

BHGE

About this Guide

This instruction manual applies to the following instruments and approved software:

SVI FF

with firmware version 1.0.0.x or higher

with ValVue* version 3.x

SVI FF DTM version 1.00.X or 1.1.0.0 or 1.2.0.x

The information contained in this manual, in whole or part, shall not be transcribed or copied without 
BHGE’s written permission.

In no case does this manual guarantee the merchantability of the positioner or the software or its 
adaptability to a specific client needs.

Please report any errors or questions about the information in this manual to your local supplier or visit 
valves.bhge.com.

DISCLAIMER

THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC 
REFERENCE INFORMATION IN ADDITION TO THE CUSTOMER/OPERATOR’S NORMAL OPERATION AND 
MAINTENANCE PROCEDURES. SINCE OPERATION AND MAINTENANCE PHILOSOPHIES VARY, BHGE (BAKER 
HUGHES, A GE company LLC AND ITS SUBSIDIARIES AND AFFILIATES) DOES NOT ATTEMPT TO DICTATE 
SPECIFIC PROCEDURES, BUT TO PROVIDE BASIC LIMITATIONS AND REQUIREMENTS CREATED BY THE 
TYPE OF EQUIPMENT PROVIDED.

THESE INSTRUCTIONS ASSUME THAT OPERATORS ALREADY HAVE A GENERAL UNDERSTANDING OF THE 
REQUIREMENTS FOR SAFE OPERATION OF MECHANICAL AND ELECTRICAL EQUIPMENT IN POTENTIALLY 
HAZARDOUS ENVIRONMENTS. THEREFORE, THESE INSTRUCTIONS SHOULD BE INTERPRETED AND 
APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND 
THE PARTICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE.

THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO 
PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, 
OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR 
PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE CUSTOMER/OPERATOR'S PURPOSES 
THE MATTER SHOULD BE REFERRED TO BHGE.

THE RIGHTS, OBLIGATIONS AND LIABILITIES OF BHGE AND THE CUSTOMER/OPERATOR ARE STRICTLY 
LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE 
EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY BHGE REGARDING THE 
EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS.

THESE INSTRUCTIONS ARE FURNISHED TO THE CUSTOMER/OPERATOR SOLELY TO ASSIST IN THE 
INSTALLATION, TESTING, OPERATION, AND/OR MAINTENANCE OF THE EQUIPMENT DESCRIBED. THIS 
DOCUMENT SHALL NOT BE REPRODUCED IN WHOLE OR IN PART TO ANY THIRD PARTY WITHOUT THE 
WRITTEN APPROVAL OF BHGE.

Copyright

All information contained herein is believed to be accurate at the time of publication and is subject to 
change without notice. 

Copyright 2019 by Baker Hughes, a GE company LLC. All rights reserved.
 PN 720036097-888-0000 Rev. E.

Содержание Masoneilan SVI FF

Страница 1: ...Masoneilan SVI FF Advanced Performance Digital Positioner Bench Quick Start Rev E Instruction Manual BHGE Data Classification Public...

Страница 2: ...AL EQUIPMENT IN POTENTIALLY HAZARDOUS ENVIRONMENTS THEREFORE THESE INSTRUCTIONS SHOULD BE INTERPRETED AND APPLIED IN CONJUNCTION WITH THE SAFETY RULES AND REGULATIONS APPLICABLE AT THE SITE AND THE PA...

Страница 3: ...This procedure consists of the following major steps 1 Physical Setup on page 4 2 Software Install and Configuration on page 5 3 Performing Basic Configuration on page 11 4 Optional Find Stops and Ope...

Страница 4: ...486 Connect the leads to the power hub any terminal as follows red lead to green to S black lead to c Plugging the USB plug into USB 8486 into the laptop PC Figure 1 Bench Setup Equipment 4 Mount the...

Страница 5: ...on upgrade via the NI website If NI FBus does not start various tools exist including NI Interface Configuration Utility and NI Dialog utility which are useful in analyzing communications issues ValVu...

Страница 6: ...the advanced features of both ValVue and the SVI FF DTM You then have an additional 30 day period with just standard features after which you must register to continue using the product We strongly e...

Страница 7: ...ppears Figure 3 DTM Library Management 5 Click Update and once the DTM Updates list refreshes select the GE NI FBUS FF DTM and the SVI FF and click Add Sel 6 Click OK to close DTM Library Management d...

Страница 8: ...FF H1 Interface to Network View Figure 5 Figure 5 Network View 9 Right click on the FF H1 Interface and click Add New Device and Figure 6 appears Figure 6 Add New Device 10 Connect the SVI FF to the...

Страница 9: ...the SVI FF DTM See blue box above SVI FF DTM has Address 17 14 Locate the Address field blue box click in it change the address to match the LiveList Address shown in Figure 7 marked by the red box a...

Страница 10: ...og does not appear click Upload All Parameters icon see red box in Figure 8 If you have updated the FF DTM software a dialog appears when you open ValVue 3 Click Yes and the library is updated No and...

Страница 11: ...etup the positioner properly DTM help icon Quick Start Configuration tab Device help icon Calibration tabs in the directory tree Air Action Remote Sensor Control Tuning Characterization Type Device Ad...

Страница 12: ...totune on page 14 Not successful read the Find Stops Log Note the reasons for failure If magnets are out of range then a Click Find Stops tab b Adjust the magnet noting Raw Sensor Value and picture of...

Страница 13: ...e 3 8 required travel 100 4 8 full mechanical travel 79 stop adjustment A sample procedure is 1 Click the Find Stops tab and entering 79 in Open Stop Adjustment field 2 Click the Download Selected Tab...

Страница 14: ...art Configuration Tab for Autotune to run Figure 12 on page 14 For a successful Auto Tune process the supply pressure must be at least 5 psi 34 5 kPa above the spring range WARNING This procedure move...

Страница 15: ...ct an Auto Tune Aggressiveness if necessary 3 Enter an Auto Tune Supply Pressure standard unit only 4 Click 5 When finished ensure the Transducer block is returned to Auto Appendix A Suggested NI Hard...

Страница 16: ...nd enter ValVue in the search field red arrow in Figure 15 This example downloads just ValVue3 separately there is a download that contains all the DTMs as well Figure 15 Download Center Search for Va...

Страница 17: ...If you have a previous install of ValVue3 you are prompted to uninstall first and then you must run the installer again to finish the upgrade NOTE If you are upgrading from ValVue 2 x you must update...

Страница 18: ...OK and it saves to the Windows Downloads folder NOTE For fastest installation save the download file to your laptop PC Don t install from the website 4 Open Windows Explorer and click the Windows Dow...

Страница 19: ...Versions Feature Sub feature Advanced Standard Device States Positioner State X X Positioner Alert Log X X Trend and Position Setup X Device State X X Configuration Control Configuration X X Extended...

Страница 20: ...This page intentionally left blank...

Страница 21: ......

Страница 22: ...111 Moscow Phone 7 495 585 1276 Fax 88 7 495 585 1279 Houston Texas Phone 1 281 671 1640 Fax 88 1 281 671 1735 INDIA Mumbai Phone 91 22 8354790 Fax 88 91 22 8354791 SAUDI ARABIA Phone 966 3 341 0278...

Отзывы: