58 | BHGE
® 2017 Baker Hughes, a GE company. All rights reserved.
Message on LCD /
ValVue (English)
Description
Device Action
(Warning message only or
Failsafe position)
Probable Cause
Recommended Action
MCU (Microprosessor
Unit) Self-Check error
A fatal event (watchdog, illegal interrupt,
stack overflow, data checksum) occurred
Failsafe position
A valid hidden record (in RAM)
existing upon reset indicating
that a fatal event (watchdog,
illegal interrupt, stack overflow,
data checksum) occurred twice
in a 20-second period.
S
OFT
W
ARE
ERR
OR
Software error. The operating system
failed in conducting a task.
Warning message
A valid hidden record (in RAM)
existing upon reset indicating
that a CPU exception (such as
invalid instruction ) occurred OR
invalid target mode of the
device was found
Clear the condition using
ValVue software or HART
host.
If the failure persists, replace
the device.
CALIB
RATION
ERR
OR
Calibration of Analog Outputs (AOs) failed
Warning message
Calibration of AOs was outside
the acceptable range when
attempting to calibrate.
Tank empty or wrong left/right
mounting position.
Using precision measuring
equipment, perform
calibration according to
boundary limits of AOs
AUTO
TUNE
ERR
OR
The Autotune procedure has been
cancelled. Then the procedure failed to
complete
Warning message
N/A
If required start again the
Autotune procedure
DISPLACER
HEIGHT
Error of displacer height information
Warning message
The span (in engineering units)
exceeded the displacer height
plus 8.2 mm, entered into the
instrument data base
Check the engineering unit
settings and the true
displacer height
MOUNTING
Mounting error
Warning message
Mounting configuration
(left/right) conflicted zero and
span transmitter calibration
Check and do coupling if
necessary.
Recalibrate the device.
TIME W
O
RK
ING
Working time exceeded the configurable
threshold
Warning message
N/A
Perform maintenance of
device
CURRENT
SIG
NAL
SENS
O
R
Error of 4-20 mA sensor
Failsafe position:
- Fail Low or High, user adjustable
- Fail Low only for a SIL device
Readback sensor reading was
outside the -1 to 30 mA range
for five reads in a row
Clear the condition using
ValVue software or HART
host.
If the failure persists, replace
the device.
LOOP
OUTP
UT
WARN
ING
Small mismatch between commanded and
read 4-20 mA loop output (lower than 0.32
mA)
Warning message
Resistance change of external
loop may have changed
Clear the condition using
ValVue software or HART
host.
If the failure persists, replace
the device.
4-20
LOOP
OUTP
UT
ERROR
Mismatch between commanded and read
4-20 mA loop output (lower than 0.64mA)
Warning message
Resistance change of external
loop may have changed
Clear the condition using
ValVue software or HART
host.
If the failure persists, replace
the device.
LOCAL
U
SER
I
NTERFACE
OFF
User Interface (UI) was turned off
Warning message
When ambient temperature is
lower than -15 °C (+5 °F), LCD
display is frozen. Then UI are
turned off to prevent from any
error of setting
N/A
V
OLTAGE
LOOP
L
OW
Loop voltage below threshold
Warning message
Loop voltage or power supply
voltage may have changed
Check the loop voltage and
ensure it is above 10 VDC
V
OLTAGE
LOOP
H
IGH
Loop voltage above threshold
Warning message
Loop voltage or power supply
voltage may have changed
Check the loop voltage and
ensure it is below 40 VDC (or
30 VDC in intrinsically safe
area)
V
OLTAGE
S
HUNT
DIAG
NOSTIC
L
OW
Diagnostic (shunt) voltage below threshold
Warning message
Internal voltage may have
changed
Clear the condition using
ValVue software or HART
host.
If the failure persists, replace
the device.
V
OLTAGE
S
HUNT
DIAG
NOSTIC
H
IGH
Diagnostic (shunt) voltage above threshold
Warning message
Internal voltage may have
changed
Clear the condition using
ValVue software or HART
host.
If the failure persists, replace
the device.
Содержание Masoneilan 12400 Series
Страница 46: ...44 BHGE 2017 Baker Hughes a GE company All rights reserved...
Страница 62: ...60 BHGE 2017 Baker Hughes a GE company All rights reserved APPENDICES...
Страница 68: ...66 BHGE 2017 Baker Hughes a GE company All rights reserved APPENDIX C see following pages...
Страница 72: ...70 BHGE 2017 Baker Hughes a GE company All rights reserved APPENDIX D see following pages...