28 | Baker Hughes
© 2022 Baker Hughes Company. All rights reserved.
Orifice Size & Marking
Part #
Standard (No Mark)
Assembly: 25-1559
Orifice Only: 25-1040
Medium
M
Assembly: 25-8162
Orifice Only: 25-8075
Large
L
Assembly: 25-8163
Orifice Only: 25-8076
Table 8 - Orifice Part Numbers
Notes:
1. How to select Orifice Blocks
Double Acting Cyliner with DNGP
Cylinder
Bore Size
Stroke
Orifice Size
4-6
all
Small (Standard) Orifice Block Assy p/n 25-1559 on cylinder and 20-2915 metering
valve installed on solenoid exhaust
8-10
up to and including 12″
Medium (M) Orifice Block Assy p/n 25-8162 installed on cylinder
12-14
up to and including 12″
Large (L) Orifice Block Assy p/n 25-8163 installed on cylinder
10-12-14
larger than 12″
None
2. All Spring Return DNGP use 1/4 NPT FCV unless there is a speed requirement, then use 1/2 NPT FCV