background image

INSTALLATION

UNPACKING AND INSPECTION

2 - 2

  

I-E96-420A

®

UNPACKING AND INSPECTION

These are steps to follow for general handling:

1. Examine the module to make sure that no damage has
occurred in transit.

2. Notify the nearest Bailey Controls sales office of any dam-
age.

3. File a claim for any damage with the shipping company
that handled the shipment.

4. Use the original packing material or container to store the
module.

5. Store the module in a place with clean air; free from
extremes of temperature and humidity.

SETUP/PHYSICAL INSTALLATION

This section explains how to configure and install the NIAC02
module. The required procedures are installing the termination
module and connecting the calibration signal wiring and termi-
nation cables. 

The calibration slot should be as close to the master module as
possible for both internal and external calibration. 

Switch Settings

The calibration select switch selects the source for the calibra-
tion voltage. When set to INT CAL, the switch selects the inter-
nal calibration terminals (wired from the NIAM02 module) on
TB1 as the source for the calibration voltage. When set to EXT
CAL, the switch selects the external calibration terminals
(wired from the external millivolt source) on TB1 as the source
for the calibration voltage.

Cable Installation

Use the NKTU02, NKTU12, or NKTM01 cable to connect the
NIAC02 module to an empty slot in the module mounting unit.
This slot will be the calibration slot. To calibrate an IMASM02
Analog Slave Module, remove it from its normal position and
insert it into the calibration slot. The NKTM01 cable is a flat
ribbon cable. The NKTU02 cable is a round, shielded cable with
PVC jacket. The NKTU12 cable is a round, shielded cable with
non-PVC jacket. 

Figure 

2-1

 shows the cabling from the NIAC02 calibration

module to the IMASM02 slave module. Table 

2-1

 lists the

NIAC02 module cable connections.    

Содержание Infi 90 NIAC02

Страница 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 420 Analog Input Calibration Module NIAC02...

Страница 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Страница 3: ...Calibration voltages pass from the IMAMM02 and IMAMM03 Analog Master Modules or an external millivolt cali bration source to the IMASM02 slave module This manual explains how to install and use the N...

Страница 4: ...through 4 2 Original 5 1 Original A 1 Original Index 1 Original When an update is received insert the latest changed pages and dispose of the super seded pages NOTE On an update page the changed text...

Страница 5: ...alling or removing a cable assigned to that slot Failure to do so could result in damage to the module p 2 3 4 1 It is strongly recommended that all power cabinet I O etc be turned off before doing an...

Страница 6: ...n manquement cette proc dure pourrait endom mager le module p 2 3 4 1 Ll est fortement recommande que toutes les alimentations armoire E S etc soient coupees avant d effectuer quelque raccord que ce s...

Страница 7: ...CTION 2 1 SPECIAL HANDLING 2 1 UNPACKING AND INSPECTION 2 2 SETUP PHYSICAL INSTALLATION 2 2 Switch Settings 2 2 Cable Installation 2 2 Module Installation 2 4 Terminal Wiring 2 4 SECTION 3 MAINTENANCE...

Страница 8: ...4 1 4 Nomenclature 1 5 2 1 NIAC02 Cable Applications 2 3 3 1 Maintenance Schedule 3 1 A 1 Address Switch Settings SW1 A 1 List of Figures No Title Page 1 1 Application Example for the NIAC02 Module 1...

Страница 9: ...e module into operation only after reading and understanding this instruction MODULE DESCRIPTION The NIAC02 module is a single printed circuit board that uses one slot in an NTMU01 Termination Module...

Страница 10: ...dule to the calibration slot for the IMASM02 module to be calibrated Signal wire terminals are at the front edge of the calibration module for internal or external millivolt source connection Each cal...

Страница 11: ...ule Support Services Describes the support services repair parts training docu mentation etc available from Bailey Controls Company Appendix A Describes the IMASM02 Thermocouple Slave Input Module HOW...

Страница 12: ...t A card cage that provides housing for INFI 90 Network 90 termination modules Table 1 3 Specifications Property Characteristic Value Power Requirements No power is required by the NIAC02 module Mount...

Страница 13: ...Nomenclature Nomenclature Description IMASM02 Thermocouple and Millivolt Input Slave Module NIAM02 Analog Master Termination Module NKTM01 Cable Termination Module Ribbon NKTU02 Cable Termination Mod...

Страница 14: ...nd static safe practices when working with modules 1 Use Static Shielding Bag Keep the modules in the static shielding bag until you are ready to install them in the system Save the bag for future use...

Страница 15: ...external calibration Switch Settings The calibration select switch selects the source for the calibra tion voltage When set to INT CAL the switch selects the inter nal calibration terminals wired fro...

Страница 16: ...VC Jacket NKTM01 cable ribbon Connects NIAC02 module to calibration slot P1 on NIAC02 module to MMU backplane 30 m 100 ft Twisted wire pair Connects NIAC02 module to NIAM02 TB1 terminal 3 and 4 on NIA...

Страница 17: ...t of the NIAC02 module 2 Align the NIAC02 module with the guide rails in the TMU card cage and insert the module Terminal Wiring The NIAC02 module connects to the internal or external cali bration sou...

Страница 18: ...connection CAUTION If input or output circuits are a shock hazard after disconnect ing system power at the power entry panel then the door of the cabinet containing these externally powered circuits m...

Страница 19: ...3 and 4 on the NIAM02 module for internal calibration or to the external millivolt source for external calibration 6 Replace the front cover The NIAC02 module is ready for operation if 1 The circuit b...

Страница 20: ...maintenance schedule MAINTENANCE SCHEDULE Execute the tasks in Table 3 1 at the specified intervals Table 3 1 Maintenance Schedule Task Interval Clean and tighten all power and grounding connections E...

Страница 21: ...ecommended that all power cabinet I O etc be turned off before doing any termination module wiring Failure to do so could result in equipment damage Do not apply power until all connections are verifi...

Страница 22: ...oved 7 Connect and verify all wiring removed in Step 4 8 Verify that wiring and cabling to the calibration module is correct 9 Fully insert the calibration module into the TMU card cage 10 Replace the...

Страница 23: ...n part number and quantity 2 Model and serial numbers if applicable 3 Bailey instruction manual number page number and refer ence figure that identifies the part Order parts without commercial descrip...

Страница 24: ...as a quick ref erence guide for personnel installing the NIAC02 module Figure A 1 shows the IMASM02 module address select switch SW1 Table A 1 lists the binary addresses for setting SW1 Refer to the...

Страница 25: ...t 1 3 Intended user 1 1 M Maintenance schedule 3 1 O Overview 1 1 R References 1 3 Related equipment 1 5 Replacement parts ordering information 5 1 Replacement procedures 4 1 S Setup 2 2 Spare parts 5...

Страница 26: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Отзывы: