INTRODUCTION
I-E96-313A
B - 1
APPENDIX B - TERMINATION MODULE (NIDI01)
CONFIGURATION
INTRODUCTION
The IMDSO04 uses an NIDI01 for termination. Jumpers on the
Termination Module (NIDI01) configure the digital outputs that
are sent to the process. The Digital Slave Output (DSO) module
outputs switch voltages of 24 VDC at 250 mA. Refer to Table
to determine the jumper setting to configure your applica-
tion. Figure
shows the terminal assignments for the digital
output signals. Refer to this figure when connecting field wiring
to the NIDI01.
Table B-1. NIDI01 Jumper Configuration
Application/Signal Type
Jumper Configuration
24 VDC
TP27137A
J1-J10
1
2
3
4
5
6
8
7
9 10
Figure B-1. NIDI01 Terminal Assignments
1
2
3
5
6
7
8
9
10 11 12 13 14 15 16 17 18
4
19 20 21 22 23 24 25 26 27 28 29 30 31 32
TERMINAL NUMBER
NOT
USED
8B
8A
7B
7A
6B
6A
5B
5A
4B
4A
3B
3A
2B
2A
1B
1A
7B
8B
7A
8A
TP27159A