18
4) Hold a container under lower right corner of
gear box with one hand while slowly raising bow
with the other. Drain completely.
5) Return bow to horizontal position. Wipe out
remaining oil with a rag.
6) Replace gasket and cover. Fasten cover with
screws.
7) Remove vent plug (Figure 10-1) with 8mm
wrench and fill gear box with approximately 1/2
pint of 90W oil, through the hole. Reinstall vent
plug.
Figure 10-1: Gearbox
10.2
Coolant Level
Maintain coolant level. Low coolant level can cause
foaming and high blade temperatures. Replace dirty
coolant; dirty or weak coolant can clog the pump,
cause crooked cuts, a low cutting rate and/or
permanent blade damage. To fill tank, pour coolant
into hole through strainer cup to about 80% of full
capacity. Full capacity is 9 liters (2.5 gal). Follow
coolant manufacturer’s instructions for proper use
and disposal.
10.3
Additional Servicing
Any additional servicing on the band saw should be
performed by an authorized service representative.