background image

 

 

 

Safety Information 

For the safety of installation personnel and for the protection of the equipment from damage, 
please read all safety warnings. If you have any questions concerning the warnings, before 
installing or powering on the base station contact the Baicells support team. 

Warning

 IMPORTANT SAFETY INSTRUCTIONS 

This warning symbol means danger. You are in a situation that could cause bodily injury. Before 
you work on any equipment, be aware of the hazards involved with electrical circuitry and be 
familiar with standard practices for preventing accidents. 

 

 

Warning

 Read the installation instructions before you connect the system to its power 

source. 

 

Warning

 Installation of the equipment must comply with local and national electrical 

codes. 

 

 Warning

 This  product  relies  on  the  existing  building  or  structure  for  short-circuit 

(overcurrent) protection. Ensure that the protective device is rated no greater than 20A. 

 

Warning

 Do not operate this wireless network device near unshielded blasting caps or 

in an explosive environment unless the device has been modified and qualified for such use.

 

 Warning

 In  order  to  comply  with  the  United  States  Federal  Communications 

Commission  (FCC)  radio  frequency  (RF)  exposure  limits,  antennas  should  be  located  at  a 
minimum of 20 centimeters (7.9 inches) or more from the body of all persons. 

 

 

 
 

 

Содержание Nova-243

Страница 1: ...Nova 243 Outdoor 2x10W TDD eNodeB Installation Guide December 2019 Version 1 7...

Страница 2: ...consent of Baicells Technologies Inc The Baicells logo is a proprietary trademark of Baicells Technologies Inc Other trademarks mentioned in this document belong to their owners Disclaimer The informa...

Страница 3: ...y asked questions by searching the database under Baicells Resources FAQs Support How to open a support ticket or process an RMA and the Support Forum are at Baicells Support Contact Us Baicells Techn...

Страница 4: ...s Warning Read the installation instructions before you connect the system to its power source Warning Installation of the equipment must comply with local and national electrical codes Warning This p...

Страница 5: ...7 Open a CloudCore Account 13 3 Installation 14 3 1 Process Overview 14 3 2 Attach Mounting Bracket or Hooks to eNB Unit 14 3 3 Optional Attach GPS Antenna to eNB 15 3 4 Connect Cables 17 3 5 Power on...

Страница 6: ...Antenna to eNB Port 16 Figure 3 9 RF Antenna Connectors 18 Figure 3 10 Connect Ethernet Cable 18 Figure 3 11 Connect Power Cable 18 Figure 3 12 Grounding Protection 19 Figure 3 13 LEDs 19 Figure 3 14...

Страница 7: ...red so that installation is simplified and connection to the core network is plug and play Baicells provides operators with local and Web based Graphical User Interface GUI applications to configure a...

Страница 8: ...requested Complies with 3GPP Release 9 standards 5 10 15 20 MHz operating bandwidth Throughput up to 112 Mbps downlink DL 20 Mbps uplink UL 20 MHz Configurable TDD 1 3 2 2 or 3 1 DL to UL transmissio...

Страница 9: ...r to Table 2 1 for cables and wire required for eNB installation The cables are available through Baicells suppliers Table 2 1 Materials Item Description Power Cable Gauge Less than AWG16 e g AWG14 Le...

Страница 10: ...escription ACT Green Steady On Active cell site normal transmissions OFF Inactive cell site the transmitting channel is not working RUN Green Fast flash 0 125s on 0 125s off The eNB is booting up Slow...

Страница 11: ...ironment When determining where to place the eNB you need to consider factors such as climate hydrology geology the possibility of earthquakes reliable electric power and transportation access Refer t...

Страница 12: ...nding as near as possible to the equipment Ensure that the connection of the grounding points and the ground bar are tight Rustproof the terminals using rust preventing paint anti oxidation coatings g...

Страница 13: ...ttps cloudcore cloudapp net cloudcore Figure 2 4 CloudCore Login Step 2 Click on the Sign up button Step 3 Complete the mandatory fields and again click on Sign up You will receive an email from Baice...

Страница 14: ...e eNB will be installed on a support pole or on a wall 3 1 Process Overview Figure 3 1 provides a high level overview of the installation process Figure 3 1 Installation Process Overview 3 2 Attach Mo...

Страница 15: ...Wall Mounting Hooks 3 3 Optional Attach GPS Antenna to eNB If you are going to install an optional external GPS antenna you will need to install a GPS antenna lightning arrestor before connecting the...

Страница 16: ...x the GPS antenna on the GPS mounting bracket 1 using an M4 screw Figure 3 6 Vertical installation is required Figure 3 7 shows the completed installation of the GPS antenna on the top of the eNB Figu...

Страница 17: ...l to identify each cable Optical fiber cable layout guidelines Do not coil or twist the cable Do not bind on the turn in the cable Do not pull or weigh down the optical fiber Grounding layout guidelin...

Страница 18: ...nnect Power Connector Connect the 48V DC power connector to the PWR interface on the eNB Figure 3 11 red cable Figure 3 11 Connect Power Cable 3 4 5 Connect Grounding Cable The grounding terminals are...

Страница 19: ...escriptions that were provided in Table 2 2 Figure 3 13 LEDs After checking to see that all connections are secure and the eNB hardware is operating as intended go to the next step in section 3 6 to e...

Страница 20: ...150 1 The eNB GUI login screen will open Figure 3 14 Use the default user name and password of admin admin Figure 3 14 GUI Login 2 Configure the eNB to connect to the Baicells CloudCore a Go to the BT...

Страница 21: ...The range of each is 1 to 100 digits You can also enter an access controller name and service name Static IP IPv4 address netmask and gateway or IP address of the Domain Name Server DNS where multiple...

Страница 22: ...3 19 LGW should be enabled b Select one of 3 LGW modes i NAT Network Address Translation modifies the network address in the IP packet headers To reach a CPE remotely enter https eNB IP address 5 last...

Страница 23: ...CloudCore you must use PLMN ID 314030 and MME IP addresses 10 3 0 9 and 10 5 0 9 b Bandwidth setting may be 5 10 15 or 20 MHz c Select the correct frequency within the band for this eNB to use d Selec...

Страница 24: ...used to identify a cluster of cell sites Enter a value between 0 65535 for each unique TAC ID in your network k The RF Status field is used to enable or disable RF transmissions In closed environment...

Страница 25: ...ollow the steps below 1 Open a Web browser and enter the CloudCore address https cloudcore cloudapp net cloudcore 2 Go to eNB Monitor and check the Active Status column as shown in Figure 3 22 If the...

Страница 26: ...tion provides guidance for pole installations and positioning the equipment on a tower roof or other outdoor structure as well as outside wall installations NOTE It does not matter if the eNB or the a...

Страница 27: ...3 8 3 1 GPS Positioning Considerations Consider the following concerning GPS positioning when installing the eNB The GPS antenna should be free of any major blocking from buildings in the vicinity Mak...

Страница 28: ...re installed securely in the proper position verify grounding and lightning protection Apply or verify reliable weatherproofing as explained in section 2 6 of this document 3 8 3 3 Install Directional...

Страница 29: ...ith expansion screws If the wainscot is less than 3 9 feet 1 2 meters tall fix the mounting pole to the wall with expansion screws and attach the base of the mounting pole to an adequate base support...

Страница 30: ...nt Antenna Type External high gain antenna compatible with eNB N Type connectors Dimensions HxWxD 17 3 x 9 5 x 5 5 inches 440 x 240 x 140 millimeters Weight 26 lbs 12 kg Future software release Softwa...

Страница 31: ...rmance statistics Fault management Local or remote software upgrade Logging Connectivity diagnosis Automatic start and configuration Alarm reporting KPI recording User information tracing Signaling tr...

Страница 32: ...Nova 243 outdoor TDD eNodeB LTE Release 9 2x10W 40 dBm 2 port 2 5 GHz B41 FCC certification 2AG32BRU3510 2501 2685 MHz IC certification 20982 BRU3510 2500 2690 MHz BRU3511 Nova 243 outdoor TDD eNodeB...

Страница 33: ...adio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not...

Страница 34: ...de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique sub...

Отзывы: