Operating Manual BaehrTec S2000
English– V101 – Status 07/2015
Page 37/52
7)
Using a small brush clean the fine filter under running tap water and make sure that
you do not damage the filter grille.
8)
Replace the fine filters (in any order) and screw them back into place until stop.
(
Attention!
fine filters only tighten
gently
). Also ensure that you do not damage the
filter mesh.
Send the device in for servicing should the device still not function correctly after
cleaning/changing the fine filters.
If you have damaged a fine filter, you can order new filters (Art-No. 22000001).
ATTENTION!
Only operate the device with an undamaged filter, as your device could
otherwise suffer serious damage.
Damage caused by dirt in the spray system is not covered by the warranty.
5.4
Cleaning the filling level contacts in the liquid tank
The BaehrTec S2000 is equipped with an electronic filling level indicator
.
Clean both filling level contacts in the tank when the liquid tank is empty and the filling level
indicator on the display still does not light up (see
Fig. 15 and 16)
with a microfibre cloth.
Your device is now ready to use again.
5.5
Easy-Clean clamping mechanism
We are delighted to inform you that your handpiece contains our newly developed,
innovative and patented Easy-Clean clamping mechanism (hereinafter referred to as "Easy-
Clean").
In a conventional clamping mechanism, the dirt that arises when working can cause an
instrument you are operating with your handpiece to stop, even though the motor is running.
This can be accelerated even further by creams, oils, fats or the like. The consequence: The
clamping mechanism is no longer functional or only functional to a limited extent and
previously needed to be sent to the factory for maintenance and cleaning. To save you from
doing this in future, we have developed Easy-Clean. You can easily clean Easy-Clean
yourself without great expense or effort.
The cleaning intervals of the Easy-Clean grips vary by the number of pedicures per day.
Recommendation: With an average 8 to 10 procedures per day the grips should be cleaned
every 14 days with the included tools. However, the grips must be cleaned at least 1 x per
month!
It is essential that you read this section with the utmost care! It contains
important information on protecting yourself, others and the device from
damage! It must only be used by trained professionals.
Never perform cleaning work or change a filter on a device that is still
connected to the mains. Turn off the device at the main switch beforehand and
disconnect it from the power supply.
Caution – risk of injury! Never try to perform cleaning work on the
handpiece while the handpiece motor is running. The handpiece motor
must be switched off.