18
5. Settings
The necessary basic settings required for
the control function are made in the menu
“5. Settings”.
This does not under any circum-
stances replace the safety facili-
ties to be provided by the
customer!
The menu is closed by pressing the “esc”
key or selecting “Exit settings”.
Settings
Fi
lter
pum
p
5.3. Filter pump
Filter pump run time
The BADU®Eco Logic controls the fi ltering time of the pump in which the fi lte-
ring times for the minimum hourly and daily fi ltering are taken into consideration.
5.3.1. Min. hourly fi ltering time
This menu is used to set the hourly fi ltering time.
The pump is switched on at the end of the hour for the set time.
Setting range: off , 1 min. - 60 min. / Default: off
5.3.2. --
5.3.3. Enable fi lter pump
In this menu the setting for enabling the fi lter pump via the sensor input S4 can
be made. In addition the clear rinse time and the clear rinse level can also be
set for Easytronic.
Setting range: simple, Easytronic/Default: simple
5.3.4. Clear rinse time
The fi lter pump will run for the time set here after each release to rinse the system.
Setting range: 0 - 30 Min/Default: 5 Min
5.3.5. Clear rinse stage
Filter pump stage during clear rinse time.
Setting range: 1 - 3/Default: 2
Содержание Eco Logic
Страница 28: ...28 ...
Страница 29: ...29 ...
Страница 30: ...30 Commissioner s notes ...
Страница 32: ... Here you will find further FAQs and notes regarding the BADU Eco Logic ...