Programming
Page 24/43
UF_iS4000_BA_02_1811
PIN
The different menus and parameterings can be secured via three password levels.
•
Administrator PIN
•
Service PIN
•
User PIN
The password protection is a 6-digit PIN which is parametered on [000000] and deactivated
at the factory.
At the first time activate the password protection Control = On
Enter login with the password 000000.
Now you can go back to the PIN again and enter [User], [Service] and [Admin] password.
Once the password protection has been activated, please enter your PIN under Login;
the symbol (lock open)
appears. The PIN grants you access to either Administrator, Service or
User level with the respective access rights (marked with A, S and U in the manual). You can now
move to the menu and enter your parameters.
Without login, you can read all parameters, but cannot change them.
Control
Activate and deactivate the PIN
User
User logged in with this PIN will have access to all user-levels. Users at this
level do not have access to Service or Admin functions.
Service
User logged in with this PIN will have access to both service and user-level
procedures. User at this level will not have access to administrative functions.
Admin
User logged in with this PIN will have access to both service and user-level
procedures.
Random Number
In case of losing PIN read the random number. This number has to be sent to
Badger Meter support, which is able to generate the Emergency PIN.
Between reading random number and entering received emergency PIN, do
no try to play with emergency PIN and do not restart the meter.
Emergency PIN
In case of losing PIN read the random number. This number has to be sent to
Badger Meter support, which is able to generate the emergency PIN.
Between reading random number and entering received emergency PIN, do
no try to play with emergency PIN and do not restart the meter.
Login
Login
Once the password protection has been activated, please enter your PIN