Digital Input
Digital input lets you reset totalizers (Remote reset), interrupt flow measurement
(PosZeroReturn) or ADE.
Input switching is provided by applying an external potential of 5 to 30 VDC
or by an internal voltage source of 24 VDC (Analog output if not used).
Digital Outputs
You can configure functional operation of the 2 digital outputs. You can select e.g
“forward pulse” for the digital output and define the pulses per totalizer unit via
“pulse scale”.
Digital outputs 1 and 2
The two outputs can be operated as open collector passively or actively.
Passive output
Active output (if analog output is not used)
Solid State Relay
The solid state relay is functional linked with output 2. See functions of output 2.