Programming
Changing Custom Units
1� Highlight
CUST
and press
ENTEO
�
The display populates with additional icons that need to be modified for
custom units�
2� Press
F2
(custom label)� Use the soft keys in conjunction with the numeric
keypad and
UP/DOWN
keys to create a custom label, then press
ENTEO
� See
and
for button functionality�
3� On the confirmation screen, press
ENTEO
to confirm the new custom unit� The
new label displays in the selection list�
4� Press
F3
(conversion) to assign a conversion factor for this custom unit� The
number entered will be a factor of gallons-per-minute�
5� Press
ENTEO
to save the change�
6� On the confirmation screen, press
ENTEO
to confirm the change�
As a conversion factor example, if you enter 2, the custom unit is equivalent to
2 gallons per minute� If you enter 0�5, the custom unit is equivalent to 1/2 gallon
per minute�
Display Precision
The
Display Precision
parameter determines the resolution of a value indicated by
the number of digits after the decimal place�
1� Highlight the drop-down menu for
DISPLAY POECISION
and press
ENTEO
�
2� Press the
UP/DOWN
keys to highlight a display precision from 1…4
and press
ENTEO
�
Oadix
The
Radix
parameter determines if a period or comma is used to represent a
decimal place�
1� Highlight the drop-down menu for
OADIX
and press
ENTEO
�
2� Press the
UP/DOWN
keys to highlight either the decimal point ( � ) or the
comma ( , ) and press
ENTEO
�
Page 28
July 2016
CTL-UM-01723-EN-01