SPECIFICATIONS
Flow Range
0 .03…12 m/s
Accuracy
± 0 .3% of reading, ± 2 mm/s
Conductivity
Min . 5 µS/cm (20 µS/cm for demineralized water)
Fluid Temperature
With Remote AmplifierE:
PTFE 302° F (150° C),
Hard rubber 178° F (80° C)
With Meter-Mounted AmplifierE:
PTFE 212° F (100° C),
Hard rubber 178° F (80° C)
Ambient Temperature
–4…140° F (–20…60° C)
Flow Direction
Uni-directional or bi-directional
Analog Output
0/4…20 mA / 0…10 mA, flow direction is displayed on a separate status output
Pulse Output
2 open collectors, passive 32V DC, 0…100 Hz 100 mA, 100…10,000 Hz 20 mA, optional
active
Frequency Output
Max . 10 kHz (open collector)
Communication
RS232, RS422, RS485 Modbus RTU
Empty Pipe Detection
Field-tunable for optimum performance based on specific application
Min-Max Flow Alarm
Programmable outputs 1…100% of flow
Low Flow Cutoff
Programmable 0…10% of maximum flow
Galvanic Separation
Functional 500 volts
Pulse Width
Programmable 5…2000 ms
Coil Power
Pulsed DC
Repeatability
0 .1%
Display
Two lines x 15 characters (7 on top + 8 on bottom), LCD display
Programming
3 external buttons
Units of Measure
Gallons, ounces, MGD, liters, cubic meters, cubic feet, imperial gallon, barrel, hectoliter and
acre feet
Power Supply
92…275V AC (50 / 60 Hz), <13 VA optional 9…36V DC, 4W
Amplifier Housing
Powder-coated aluminium die cast
Detector Housing
Carbon steel
Linear Materials
Hard Rubber, PFA, PTFE
Electrodes Materials
Standard
: Hastelloy C
Grounding Rings
Stainless steel
Mounting
Detector-mount or remote wall mount
Approvals
NSF Listed: Models with hard rubber liner 4" size and up; PTFE liner, all sizes
Cable Insertion
2 x M 20
Process Connection
Flange: DIN, ANSI, JIS, AWWA
Nominal Pressure
Up to 232 psi (16 bar)
Protection Class
Standard
: NEMA 4X (IP67);
Optional
: NEMA 6P
Pollution Degree
2
Installation Category
II
Altitude
2500 m
Humidity
90% R .H . max .
Electrical Supply
100…240V AC (±10%) . 50/60 Hz, 15 Watts
NOTEE:
Mains supply voltage fluctuations are not to exceed ±10% of the nominal voltage
supply .
Specifications
Page 34
January 2018
MAG-UM-00379-EN-04