CONNECTING AN ORION ADE ENDPOINT TO THE M1000 METER
OTEE:
N
Connect the endpoint as described . The endpoint automatically updates within one hour . You can force an update
using the Endpoint Utility . See the endpoint user manual for programming information .
Wiring
To connect the ADE endpoint, connect:
ADE Wire
M1000 Terminal
Red (Power/Clock)
Input +
Green (Data)
Out 1 +
Black (Ground)
Out 1 –
Connect a jumper wire from Out 1 negative (–) to INPUT negative (–) .
+IN
-
+OU
T1
-
+OU
T2-
black ADE_GROUND
green ADE_DATA
red ADE_CLOCK
Programming
Changing the following settings automatically configures
Input
and
Output 1
for ADE .
To program the M1000 meter for the endpoint to Output #1 (forward flow):
1 . Navigate to
COMMUNICATION > ADE > CONTROL
.
2 . Use the arrows to change the values, then press
EXIT/SAVE
.
3 . Repeat steps 1 and 2 for
Control, Protocol, Dials
and
Resolution (
the
Resolution
range is 0 .0001…10,000) .
4 . Press
EXIT/SAVE
.
Connecting an ORION ADE Endpoint to the M1000 Meter
Page 33
January 2018
MAG-UM-00379-EN-04