Operational Safety
WARNING: Inhalation of high concentrations of refrigerant vapors is harmful and
may cause heart irregularities, unconsciousness, or death. Deliberate inhalation of
refrigerants is extremely dangerous and may cause death. Vapor reduces the oxygen
available for breathing and is heavier than air. Decomposition products are
hazardous. Liquid contact can cause frostbite. All refrigerant containers, equipment,
and hoses are under high pressure.
•
Avoid breathing high concentrations of vapors.
•
Use with sufficient ventilation to keep operator exposure below recommended limits,
especially in enclosed and low lying areas.
•
Avoid contact of liquid with eyes and prolonged skin exposure.
•
Wear safety goggles and protective gloves.
•
Make sure the power switch is in the OFF position before plugging this equipment into
an AC power source.
•
Unplug unit before servicing; otherwise, an electrical shock hazard will be present when
the unit is disassembled.
•
Use caution when connecting or disconnecting hoses. Improper usage may result in
refrigerant burns (frostbite). If a significant refrigerant leak occurs, proceed immediately
to a well-ventilated area.
•
Do not apply open flame or heat unit above 125
°
F.
•
Do not allow refrigerants to contact open flame. Decomposition will occur. Inhalation of
decomposition is harmful.
•
First Aid:
Breathing
: If high concentrations of refrigerant vapors are inhaled, immediately remove
the person(s) to fresh air. Keep calm. If not breathing, give artificial respiration. If
breathing is difficult, give oxygen. Call a doctor. Do not give epinephrine or similar drugs.
Eye:
In case of liquid contact, immediately flush eye with water. Seek medical attention.
Skin:
Flush with water. Treat for frostbite by gently warming the affected area.
CAUTION:
All refrigerant hoses, recovery tanks, refrigerant lines, the STINGER unit,
and other vessels containing refrigerants should be handled at all times as if under high
pressure.