Instruction 24-9428
3
Fyrite Tech
2.0 TECHNICAL CHARACTERISTICS
The Analyzer Directly Measures and Displays:
• Flue Gas O
2
content ..................................... 0.0 to 20.9% O
2
• Stack Temperature ....................................... 0 to 999 °F (–18 to 537 °C)
• Ambent Temperature .................................. 32 to 212 °F (0 to 100 °C)
• Flue Gas CO content (Model 60) ................. 0 to 2,000 ppm CO
The Analyzer Computes and Displays:
(when the measured oxygen level s below 17.9 %)
• Combustion Efficiency
.................................. 0.1 to 99.9%
• Flue Gas CO
2
content ................................... 0.0 to a fuel dependent
maxmum value n %
• Flue Gas CO Ar-Free content (Model 60) ... 0 to 9,999 ppm
• Excess Ar ..................................................... 0 to 400%
Fuel Selection:
(F1 thru F4 denotes the fuel selected as dsplayed on the LCD)
• Natural Gas (F1)
• Ol #2 (F2)
• LPG (F3)
• Kerosene (F4)
Normal Operating Conditions:
Temperature:
• Analyzer ....................................................... 32 to 104 °F (0 to 40 °C)
• Probe ............................................................. 1,000 °F max (538 °C) at
5" nserton
Humdty ............................................................. 15 to 90% RH,
Non-Condensng
Power Requirements
.................................... Four ‘AA’ Alkalne batteres
Operating Time
.............................................. Up to 18 hours contnuous
(pump runnng and back-
lght off)
Warm Up Time
................................................ 60 seconds
Содержание Fyrite Tech 50
Страница 6: ...Fyrite Tech Instruction 24 9428 iv Notes...
Страница 46: ...Instruction 24 9428 40 Fyrite Tech Notes...
Страница 47: ...Instruction 24 9428 41 Fyrite Tech Notes...