Section 16: Adjusting the Needle Height with Cylinder
Height Gauge (Continued)
• Slide the cylinder tool gently out, to be against
the needle .
• Sight through the needle eye and compare the
upper and lower levels of the eye with the cylinder
tool groove. The eye should be aligned with the
white groove of the gauge. If an adjustment is
necessary, hold onto the needle bar with one
hand, while loosening the screw with your other
hand. Raise or lower the needle bar as needed.
• Rotate the needle bar until the hole in the needle
bar clamp thread guide is straight forward.
• Reinstall the hook and set loop lift at 2.2 mm and
reset needle distance. (See Adjustment of the Loop
Lift and Needle Distance Section 13, page 33.)
• Reinstall the stop finger and needle plate.
• Rotate the cylinder height gauge until the flat
is down.
• Rotate the handwheel until the needle is in the
lowest position.