M
A
I
N
T
E
N
A
N
C
E
42
Your Baby Lock Euphoria will operate at best performance if it is kept clean at all times.
Your Baby Lock's major moving parts are well protected and do not need to be oiled. However, we
recommend using the cleaning brush often during garment construction in order to keep lint off the
needle bar, the feed dog mechanism and looper. For periodic interior cleaning, lubrication, and
adjustments, contact your Baby Lock retailer.
TO REMOVE NEEDLE PLATE PROCEED AS FOLLOW:
1. For safety reasons, unplug main power cord.
2. Raise and remove presser foot.
3. Remove needles from needle clamp.
4. For easy access to the needle plate lock pin set screw, raise needle clamp to its highest position
and open the front cover and front table (fig. A).
5. Place allen screwdriver (1.5mm) into allen screw and loosen needle plate pin holder screw. See
fig. B for location of screw.
6. Remove needle plate lock pin (fig. B) and remove needle plate front screw.
7. Open left side cover of machine and remove needle plate.
8. Clean machine (fig. C).
9. Place needle plate onto machine and insert needle plate lock pin.
10. Tighten allen screw of the needle plate lock pin and check to be sure that top of needle plate lock
pin is flush with needle plate.
11. Place needle plate front screw and tighten screw.
Note:
For better stitch performance, make sure needles C-1, C-2,and C-3 do not touch either side of
needle plate hole.
Cleaning
A
B
C
Needle plate
front screw
Needle plate
lock pin
Needle plate lock
pin holder screw