3 General Description
©
b2 electronic
GmbH
DHV0078 b2 EN
15
3.2
Design Features
To assure that the workplace is safe and that operators can fulfil their
responsibilities with ease, the HVA provides the following features.
Feature
Purpose/application
Advantage
Optimized frequency
Selection/automatic load
measurement
•
To test capacitive loads
•
No instrument restart necessary
•
Facilitates testing
•
Limits number of
connections to the DUT
Fully automatic test
sequences
•
To test according to IEEE or other
standards
•
Facilitates complex testing
•
Facilitates test repetition
Real time display
•
To indicate instantaneous output
voltage display.
•
Facilitates testing
Load independent
output
•
To indicate true symmetrical
sinusoidal and square wave
waveforms output
•
Facilitates testing
Built-in memory
•
To save test sequences
•
To save test reports
•
Facilitates test repetition
•
Facilitates documentation
Arc management
•
To provide short-circuit protection
•
To allow for fault conditioning
•
Limits test interruptions
commonly encountered
when using conventional HV
test instruments that
immediately trip on arc
detection.
Automatic load
measurement
•
To limit connections to the DUT
•
Facilitates testing
Intelligent design
•
To avoid moving parts and need
for lubrication
•
Reduces maintenance
•
Improves instrument
durability and reliability
Instrument Lock-
Key switch
•
To prevent unauthorized use
•
Improves safety
Local and remote
emergency OFF
switches
•
To shut down operations in
emergency situation
•
Improves safety
Fully integrated
discharge and transient
circuit
•
To ground the DUT after testing
•
To protect the unit from transient
over voltages
•
Improves safety
•
Protects instrument
Initial load clearance
test at reduced voltages
•
To check automatically for shorts
or grounds, during load
measurement, before test
initiation
•
Improves safety
Содержание HVA120
Страница 2: ...1 Introduction 2 DHV0078 b2 EN b2 electronic GmbH...
Страница 11: ...2 Safety b2 electronic GmbH DHV0078 b2 EN 11...
Страница 22: ...4 Design and Construction 22 DHV0078 b2 EN b2 electronic GmbH Switches and controls Front panel HVA34...
Страница 33: ...5 Test Procedure b2 electronic GmbH DHV0078 b2 EN 33 Connection diagram vacuum bottle test...
Страница 47: ...5 Test Procedure b2 electronic GmbH DHV0078 b2 EN 47 5 5 Discharge Status...
Страница 62: ...11 Declaration of Conformity 62 DHV0078 b2 EN b2 electronic GmbH 11 Declaration of Conformity HVA34...
Страница 63: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 63 HVA30 5...
Страница 64: ...11 Declaration of Conformity 64 DHV0078 b2 EN b2 electronic GmbH HVA30 7 HVA40 5 HVA54 3...
Страница 65: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 65 HVA54 5...
Страница 66: ...11 Declaration of Conformity 66 DHV0078 b2 EN b2 electronic GmbH HVA60...
Страница 67: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 67 HVA68 2...
Страница 68: ...11 Declaration of Conformity 68 DHV0078 b2 EN b2 electronic GmbH HVA90 HVA94...
Страница 69: ...11 Declaration of Conformity b2 electronic GmbH DHV0078 b2 EN 69 HVA120...