2. SPECIFICATIONS

 

                               

 

 

Model # 

PGE-W2 

PGE-W5 

PGE-W10 

Maximum Capacity 

2000Kg/4400lb 

5000Kg/11000lb  10000Kg/22000 

Resolution 

1:80000 

1:80000 

1:80000 

Minimum 

1kg/.5lb 

2kg/1lb 

2kg/5lb 

Operating Temps 

14-104 degrees 

  14-104 degrees 

    14-104 

degrees 

Power 

9v/800mA 

9v/800mA 

9v/800mA 

Display 

1.2” LED Display 

Unit of Measure 

Lb/ Kg 

Shipping Weight 

35 lb 

50 lb 

77 lb 

 
 
 

Содержание WorldWEIGH PGE-W Series

Страница 1: ...V1 19F PGE W series Crane Scale Technical Manual ...

Страница 2: ...Specifications 2 3 Introduction And features 3 4 Precautions 4 5 Installation 4 6 Battery and Charging 4 7 Name and function 5 8 Operation 7 1 Basic operation 7 2 Auto Sleep 7 9 Functions Descriptions 7 a Parameter Settings 8 b Calibration 9 c Error Codes 10 d Drawing 11 ...

Страница 3: ...PGE W series crane scale Technical Manual 1 1 DIMENSIONS A B C D L PGE W2 10 6 6 8 1 97 1 85 24 PGE W5 11 7 7 3 1 97 1 97 29 PGE W10 11 7 7 3 2 17 2 75 33 ...

Страница 4: ...um Capacity 2000Kg 4400lb 5000Kg 11000lb 10000Kg 22000 Resolution 1 80000 1 80000 1 80000 Minimum 1kg 5lb 2kg 1lb 2kg 5lb Operating Temps 14 104 degrees 14 104 degrees 14 104 degrees Power 9v 800mA 9v 800mA 9v 800mA Display 1 2 LED Display Unit of Measure Lb Kg Shipping Weight 35 lb 50 lb 77 lb ...

Страница 5: ...ogy allows the instrument to perform in all measuring functions input output automatic controls and sequences necessary for the operation of the weighing systems Features 1 2 Large LED display Rechargeable battery operation Selectable reading resolution zero tare function Remote controller Moisture proof design 4 PRECAUTIONS Do not install the crane scale in direct sunlight Avoid sudden temperatur...

Страница 6: ...e the battery insert the adaptor pin to the jack The scale does not needs to be turned on The battery should be charged for 24 hours for full capacity Just under the zero indicator there is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is green the battery is fully charged If it is Red the battery is...

Страница 7: ...activated STABLE Indicates that the scale is stable ZERO Indicates that scale is stable at zero Key Board ON OFF CHANGE UNIT ZERO ON OFF Used to turn the scale on off CHANGE Used to change mode In setting mode used to change item UNIT Used to change unit from lb to kg In setting mode used to escape and in calibration mode used to change decmal ZERO TARE Resets to zero and used to enter a tare weig...

Страница 8: ...ne key is standby no function Please pull out the antenna before operate the remote controller The remote controller operates up to a distance of around 75 feet but this is dependant on the operating environment Remote key functions same as the scale keys Key 1 For displaying sleep Key 2 For entering Zero Key 3 For changing division size Key 4 For changing unit of measure lb kg ...

Страница 9: ...e when current reading less then 2 of capacity press this key will do zero operate this means tare weight must 2 of capacity D Change units To change from lb to kg s press the UNIT key LED labeled lb will be lit when in lb unit of measure E Change division You can use the CHANGE key to change division size refer to F0 in parameters F Overload Warning Please do not add item that is over the maximum...

Страница 10: ...2 lb 1 lb 5 lb 5 kg 2 kg 1 kg 1 kg 500 g 200 g 5t 20 lb 10 lb 5 lb 5 lb 2 lb 1 lb 10 kg 5 kg 2 kg 2 kg 1 kg 500 g 10t 20 lb 20 lb 10 lb 10 lb 5 lb 2 lb 20kg 10kg 5kg 5kg 2kg 1kg HIGH F1 az Set zero tracking range AZn oF AZn 0 5 AZn 1 AZn 2 AZn 4 AZN 1 F2 bt Set baud rate NOT USED 600 600bps 1200 1200bps 2400 2400bps 4800 4800bps 9600 9600bps 600 F3 sp Set ADC speed S 1 7 5 times second S 2 15 time...

Страница 11: ...n calibration weight value You can change this weight value use UNIT key to move the active digit use CHANGE key to increment a digit enter the calibration weight value Then press ZERO key to sure display show LOAD now to add calibration weight on the hook When the stable indicator is on press ZERO key again Span calibration will complete with in few seconds 9 B CHANGE CAPACITY 1 Open the Top cove...

Страница 12: ...d connecter Err 6 A D value out of range Make sure hook is empty Check the load cell connectors Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Check the load cell and connecters Err 17 Tare out of range Remove the load and restart scale again ol Over range Remove the load Re calibrate Fai l h fai l l Calibration Error Re calibrate Err p Printer error Chec...

Страница 13: ...c 1 Loop 1 2 Back Cover 1 Al 3 Screw internal hexagon 4 M4x10 4 Washer 1 SUS 5 Overlay 1 6 PCBA 1 7 Power Switch 1 8 Function Switch 3 9 Screw 4 M6x15 10 Front Cover 1 Al 11 Load Cell 1 12 Screw 4 M4x10 13 Battery Bar 2 SUS 14 Battery 1 Lead Acid 15 Battery Cover 1 Al 16 Screw 4 SUS M4x8 ...

Страница 14: ...PGE W series crane scale Technical Manual 12 B TEK Scales 1510 Metric Avenue SW Canton OH 44706 Tel 330 471 8900 Fax 330 471 8909 www B TEK com ...