PGE-W series crane scale Technical Manual
- 8 -
8. FUNCTIONS & DESCRIPTIONS
9. A. PARAMETER SETTINGS
Turn on the scale. Press ZERO and CHANGE keys both during the self
checking.
Display will show “ P1---“. Then want to press password. use
HOLD
key to move
the active digit, use
CHANGE
key to increment a digit, use
ZERO
key to sure,
default password is “000”, Display will shows “F0 di”, scale enter setting mode,
after enter mode, use
CHANGE
key to shift parameter items, use
ZERO
key to
sure, use
HOLD
key to escape current setting item.
FUNCTION
DESCRIPTION
DEFAULT
F0 di
Set resolution
Low
High
Detail information as below
cap
d (Low resolution)
d (High resolution)
2t
10lb
5 lb
2 lb
2 lb
1 lb
.5 lb
5 kg
2 kg
1 kg
1 kg
500 g 200 g
5t
20 lb
10 lb
5 lb
5 lb
2 lb
1 lb
10 kg
5 kg
2 kg
2 kg
1 kg
500 g
10t
20 lb
20 lb 10 lb
10 lb
5 lb
2 lb
20kg
10kg
5kg
5kg
2kg
1kg
HIGH
F1 az
Set zero tracking range
AZn oF, AZn : 0.5, AZn: 1, AZn: 2, AZn: 4
AZN 1
F2 bt
Set baud rate
(NOT USED)
600: 600bps, 1200: 1200bps
2400:2400bps, 4800: 4800bps
9600: 9600bps
600
F3 sp
Set ADC speed
S 1: 7.5 times/second
S 2: 15 times/second
S 3: 30 times/second
S 4: 60 times/second
S 1
F4 ip
Show internal counts
F5 sl
Set auto sleep mode
SLP 0: no auto sleep
SLP 1: auto sleep after scale empty for 5 minutes
SLP 2: auto sleep after scale empty for 10 minutes
SLP 3: auto sleep after scale empty for 20 minutes
SLP 4: auto sleep after scale empty for 30 minutes
Slp 1
F6 gv
Set gravity parameter
Use UNIT key to move the active digit, use CHANGE key
to increment a digit, use ZERO key to sure