B-TEK Scales WorldWEIGH PGE-W Series Скачать руководство пользователя страница 9

PGE-W series crane scale Technical Manual

 

 

 

- 7 -

 

 

8.

 

OPERATION 

 
1. Basic Operation 
 

A. Power on and off 

      Please  press 

ON/OFF

  key  before  you  operate  this  scale,  and  if  you  want  to 

switch off press 

ON/OFF

 key again. 

  B. Zero the scale

 

      When there is no item on the scale but reading is not zero, press the

 Zero

 key 

to make re-zero reading.    After operation, the zero indicator will on. 

      (Note,  when  current  reading  more  then  2%  of  capacity,  press  this  key  will  do 

tare operate) 

C. Tare operate 

      When you load a container, and want to weigh with goods in container later, you 

can press 

Zero

 key with container, display will show “0.00”. 

    (Note, when current reading less then 2% of capacity, press this key will do zero 

operate, this means tare weight must > 2% of capacity) 

D. Change units 

 

  To change from lb to kg’s press the UNIT key, LED labeled lb will be lit, when   

        in lb unit of measure 

E. Change division 

        You can use the 

CHANGE

 key to change division size (refer to F0 in 

        parameters) 

F. Overload Warning 

      Please  do  not  add  item  that  is  over  the  maximum  capacity.    When 

reading“--ol-”, remove the item from the scale to avoid damage to the load cell. 

2. AUTO SLEEP 

PGE-W

 series crane scale have an automatic sleep function, (to disable this 

function, see parameter F5 sl ). When weight goes under min weight (20d) 

after the settings time, 

PGE-W

 will automatically enter sleep mode. Then press 

any key to add weight on the hook, 

PGE-W

 will return to normal weighing 

mode again. 

 

 
 

Содержание WorldWEIGH PGE-W Series

Страница 1: ...V1 19F PGE W series Crane Scale Technical Manual ...

Страница 2: ...Specifications 2 3 Introduction And features 3 4 Precautions 4 5 Installation 4 6 Battery and Charging 4 7 Name and function 5 8 Operation 7 1 Basic operation 7 2 Auto Sleep 7 9 Functions Descriptions 7 a Parameter Settings 8 b Calibration 9 c Error Codes 10 d Drawing 11 ...

Страница 3: ...PGE W series crane scale Technical Manual 1 1 DIMENSIONS A B C D L PGE W2 10 6 6 8 1 97 1 85 24 PGE W5 11 7 7 3 1 97 1 97 29 PGE W10 11 7 7 3 2 17 2 75 33 ...

Страница 4: ...um Capacity 2000Kg 4400lb 5000Kg 11000lb 10000Kg 22000 Resolution 1 80000 1 80000 1 80000 Minimum 1kg 5lb 2kg 1lb 2kg 5lb Operating Temps 14 104 degrees 14 104 degrees 14 104 degrees Power 9v 800mA 9v 800mA 9v 800mA Display 1 2 LED Display Unit of Measure Lb Kg Shipping Weight 35 lb 50 lb 77 lb ...

Страница 5: ...ogy allows the instrument to perform in all measuring functions input output automatic controls and sequences necessary for the operation of the weighing systems Features 1 2 Large LED display Rechargeable battery operation Selectable reading resolution zero tare function Remote controller Moisture proof design 4 PRECAUTIONS Do not install the crane scale in direct sunlight Avoid sudden temperatur...

Страница 6: ...e the battery insert the adaptor pin to the jack The scale does not needs to be turned on The battery should be charged for 24 hours for full capacity Just under the zero indicator there is an LED to indicate the status of battery charging When the scale is plugged into the mains power the internal battery will be charged If the LED is green the battery is fully charged If it is Red the battery is...

Страница 7: ...activated STABLE Indicates that the scale is stable ZERO Indicates that scale is stable at zero Key Board ON OFF CHANGE UNIT ZERO ON OFF Used to turn the scale on off CHANGE Used to change mode In setting mode used to change item UNIT Used to change unit from lb to kg In setting mode used to escape and in calibration mode used to change decmal ZERO TARE Resets to zero and used to enter a tare weig...

Страница 8: ...ne key is standby no function Please pull out the antenna before operate the remote controller The remote controller operates up to a distance of around 75 feet but this is dependant on the operating environment Remote key functions same as the scale keys Key 1 For displaying sleep Key 2 For entering Zero Key 3 For changing division size Key 4 For changing unit of measure lb kg ...

Страница 9: ...e when current reading less then 2 of capacity press this key will do zero operate this means tare weight must 2 of capacity D Change units To change from lb to kg s press the UNIT key LED labeled lb will be lit when in lb unit of measure E Change division You can use the CHANGE key to change division size refer to F0 in parameters F Overload Warning Please do not add item that is over the maximum...

Страница 10: ...2 lb 1 lb 5 lb 5 kg 2 kg 1 kg 1 kg 500 g 200 g 5t 20 lb 10 lb 5 lb 5 lb 2 lb 1 lb 10 kg 5 kg 2 kg 2 kg 1 kg 500 g 10t 20 lb 20 lb 10 lb 10 lb 5 lb 2 lb 20kg 10kg 5kg 5kg 2kg 1kg HIGH F1 az Set zero tracking range AZn oF AZn 0 5 AZn 1 AZn 2 AZn 4 AZN 1 F2 bt Set baud rate NOT USED 600 600bps 1200 1200bps 2400 2400bps 4800 4800bps 9600 9600bps 600 F3 sp Set ADC speed S 1 7 5 times second S 2 15 time...

Страница 11: ...n calibration weight value You can change this weight value use UNIT key to move the active digit use CHANGE key to increment a digit enter the calibration weight value Then press ZERO key to sure display show LOAD now to add calibration weight on the hook When the stable indicator is on press ZERO key again Span calibration will complete with in few seconds 9 B CHANGE CAPACITY 1 Open the Top cove...

Страница 12: ...d connecter Err 6 A D value out of range Make sure hook is empty Check the load cell connectors Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Check the load cell and connecters Err 17 Tare out of range Remove the load and restart scale again ol Over range Remove the load Re calibrate Fai l h fai l l Calibration Error Re calibrate Err p Printer error Chec...

Страница 13: ...c 1 Loop 1 2 Back Cover 1 Al 3 Screw internal hexagon 4 M4x10 4 Washer 1 SUS 5 Overlay 1 6 PCBA 1 7 Power Switch 1 8 Function Switch 3 9 Screw 4 M6x15 10 Front Cover 1 Al 11 Load Cell 1 12 Screw 4 M4x10 13 Battery Bar 2 SUS 14 Battery 1 Lead Acid 15 Battery Cover 1 Al 16 Screw 4 SUS M4x8 ...

Страница 14: ...PGE W series crane scale Technical Manual 12 B TEK Scales 1510 Metric Avenue SW Canton OH 44706 Tel 330 471 8900 Fax 330 471 8909 www B TEK com ...

Отзывы: