Remote Scale:
The C100 Series can be connected to a remote base through the Remote
scale port on the left side of the scale case.
Place the remote scale platform in the position where it is to be used.
Level the scale by adjusting the four feet. Making sure it is level.
Press
key to change between remote base and local base.
Remote Scale Connection
The cable from the remote base goes to a 9 pin male DB9 connecter on the left
side of the C100 with following connections.
Note: The sense wires connections of a six wire load cell are not used, but can
be connected to the respective Excitation pins.
The remote scale provides 5v excitation.
Pin
Connection
Color on Premade cable
1 or 2
Exci5V
Red
4 or 5
Excitation-
Black
7
Signal-
Green
8
White
3
Shield
Blue