C100 Series Technical Manual
- 16 -
Parameter Setting
Menu
Sub Menu
Description
Fi off
Beep
Beep off
Beeper is turned off
Beep On in
Beeper is turned on, will be
sounded when in check weighing
limits
Beep On out
Beeper will be sounded above the
check weighing limits
El
Lite aut
Backlight will be turn on
automatically, when loaded or a
key is pressed
Lite off
Backlight is turned off
Lite on
Back light is turned on
unit
Kg
/
lb
Weighing Unit kg and lb are
enable
Kilo
Weighing Unit kg only
lb
Weighing Unit lb only
Off
0
Auto off function disable
3
Scale will turn off after 3 minutes
5
Scale will turn off after 5 minutes
15
Scale will turn off after 15 minutes
3 0
Scale will turn off after 30 minutes
F2 prt P mode
Au on
Data out put / accumulation after
unloading the balance
Au off
Data out put / accumulation after
by pressing
P cont
RS 232 data output continuously
Ser re
RS 232 data output weight only
P baud
B 600
Set the required baud
B 1200
B 2400
B 4800
B 9600
parity
8 n 1
8 bits, no parity
7 e 1
7 bits, even parity
7 o 1
7 bits, no parity
P type
Tpup
Standard printer setting
Lp50
Label Printer
U id
U id abcdef
Shows the current User ID (max 6
characters)
Sc id
Sc id abcdef
Shows the current Scale ID (max 6
characters)
Tech
Technical parameter password
protected
Содержание WorldWEIGH C100 Series
Страница 1: ...C100 Counting Scale Technical Manual V2 40...
Страница 2: ......
Страница 26: ...C100 Series Technical Manual 23 11 DRAWING...