C100 Series Technical Manual 

 

 

- 24 - 

 
Parts List 
 

No  Parts Name  

Qty  Part number  Spec 

SS Pan 

899-300025  230mmx300mm 

Plastic Pan 

899-300026  230mmx300mm 

Battery cover 

899-300067   

Battery  

899-300022  6V/4Ah 

Foam 

 

 

Rear Overlay 

 

 

Top Cover 

 

 

Name Plate 

 

 

Internal Allen Screw 

 

M6x16, 8.8 

10  Washer (M6) 

 

200-300HV 

11  Spring Washer(M6) 

 

HRC42-50 

12  Load cell upper bracket 

 

 

13  Load cell   6 lb 

899-300032  6   kg 

 

Load cell 12 lb 

899-300033  10 kg 

 

Load cell 30 lb 

899-300132  20 kg 

 

Load cell 60 lb 

899-300034  40 kg 

14  Star (+) Screw 

 

M4x16 

15  Load cell lower bracket 

 

 

16  Self thread Screw 

 

4x10 

17  Insulated Washer 

 

8x3.1x1.2t 

18  Power Socket 

 

 

19  Power Socket Spacer 

 

 

20  Power Switch 

899-300077   

21  Foot 

899-300043   

22  Key board 

899-300075   

23  Front display overlay 

 

 

24  Level bubble 

 

14.7mm 

25  Screw 

 

M4x35 

26  Front Display PBC 

899-300074   

27  Insulated Washer 

 

8x3.1x1.2t 

28  Star (+) Self thread screw 

 

M3x20 

29  Star (+) Self thread screw 

 

M4x20 

30  Hexagon Nut 

 

Zn Coating 

31  Main PBC 

899-300073   

32  Screw for D connector 

 

 

33  D type connector 

 

 

34  Hexagon nut for D connector  4 

 

 

35  Overlay 

 

 

36  Bottom Cover 

 

ABS 

37  Self thread screw 

 

4x12 

 

Dust Cover 

899-300021  Clear ABS 

 

Power Supply 

899-300042  12v 500 mA 

Содержание WorldWEIGH C100 Series

Страница 1: ...C100 Counting Scale Technical Manual V2 40...

Страница 2: ......

Страница 3: ...e to determine the Unit Weight 11 Enter a known Weight 12 Automatic update of Unit Weight 12 Check weighing of count pre set 12 Setting the checking limits 12 PLU Product Look Up 13 Storing PLU 13 Ent...

Страница 4: ...b 00005 kg 0001 kg 0002 kg 0005 kg Units of Measure lb kg Interface Bi directional RS 232 Interface Stabilization Time 2 Seconds Operating Temperature 32 F 104 F Power supply AC Adaptor 9 V 800 mA Bat...

Страница 5: ...air conditioning vents Avoid unsuitable tables The table or floor must be rigid and not vibrate Do not place near vibrating machinery Avoid unstable power sources Do not use near large users of electr...

Страница 6: ...is not damaged and that all accessories are included If equipped remove the shipping safety screw Indicated by the red label on the bottom of the C100 Accessories 1 C100 2 Power Adaptor 3 Stainless st...

Страница 7: ...ld damage the load cell inside Check the water mark If bubble is not centered adjust the leveling feet until centered Check the level when you change the location Attach the power supply cable to the...

Страница 8: ...Press key to change between remote base and local base Remote Scale Connection The cable from the remote base goes to a 9 pin male DB9 connecter on the left side of the C100 with following connections...

Страница 9: ...the total weight and displays the result as a net weight Manually enter the weight of sample also changes the unit from lb to kg if they are enabled To enter the numbers of items used as the sample un...

Страница 10: ...hing Mode Unit Weight Display Smpl of sample is very low U Wt Unit weight is below the minimum weight M Data entered into the memory Local Remote Active Scale in use Count Display CkPcs Active in Coun...

Страница 11: ...ghing functions are same for both the scales local or remote The number of weighing divisions may be less on the remote scale dependant on the total capacity of the load cell s used 3 Zero To zero the...

Страница 12: ...a tare value of 103g is entered into the 60Kg scale with 5g readability then the display will be shown 105g 5 Accumulation The C100 can totalize weight values or count quantities Manual Accumulation...

Страница 13: ...for display stability and a control beep Unload the item from the platform the weighing value is added into the memory The scale must return to come zero or negative number before adding another sampl...

Страница 14: ...ount will increase If the scale is not stable the calculation will not be completed If the weight is below zero Count display will show negative count Enter a known Unit Weight If an a known unit weig...

Страница 15: ...ect counting Press key the active high count limit will be shown Use numeric key to enter desired and if necessary press to clear Press key the active low count limit will be shown Use numeric key to...

Страница 16: ...ht to be stored can be either taken from a weighing in process or by enter manually Press display will be shown Press numeric key exp 27 Press Currently stored text will appear The first digit is flas...

Страница 17: ...8 T U V 9 W X Y Z 0 _ _ space Note that this method is only used where alpha numeric data is permitted This is used for the Description field and the User ID number Scale ID number in the parameters...

Страница 18: ...splay will be show Select the Menu Block Press key it can choose menu block one by one Enter the Selected Menu Press key to confirm what the displays shows Select the Sub Menu Press key it can choose...

Страница 19: ...sable 3 Scale will turn off after 3 minutes 5 Scale will turn off after 5 minutes 15 Scale will turn off after 15 minutes 3 0 Scale will turn off after 30 minutes F2 prt P mode Print Au on Data out pu...

Страница 20: ...9600 Baud 8 data bits No Parity Connector 9 pin socket From C100 Pin 2 Output Pin 3 Input Pin 5 Signal Ground To LP50 Pin 2 Input Pin 3 Output Pin 5 Signal Ground Connection to the LP 50 printer Set P...

Страница 21: ...will be show Ensure the platform is empty and wait for stable indicator Press to confirm Display will be show Set weight value will be required Enter the value by using numeric keys Press to confirm D...

Страница 22: ...tor Press to confirm Display will be show Apply the weight on the display indicated in chart below wait for stable indication Then press to confirm Display will be show Apply the weight on the display...

Страница 23: ...n Pi n Enter the password Default password is 0000 and press to confirm Pi n Select the scale by pressing which should be configured and press to confirm Tech local remote Use the key to select the we...

Страница 24: ...cale division 2 5 10 20 50 Di v I nc 5 Set division I nc 10 I nc 20 I nc 50 A 2t Azn 0 5d Automatic zero tracking Azn 1d Azn 2d Azn 4d 0 Auto 0 auto 0 Zero setting range after switching on the scales...

Страница 25: ...out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors Err 9 Unstable Reading Check any air variation vibration RF noise and touching some where Che...

Страница 26: ...C100 Series Technical Manual 23 11 DRAWING...

Страница 27: ...0034 40 kg 14 Star Screw 4 M4x16 15 Load cell lower bracket 1 16 Self thread Screw 4 4x10 17 Insulated Washer 4 8x3 1x1 2t 18 Power Socket 1 19 Power Socket Spacer 1 20 Power Switch 1 899 300077 21 Fo...

Страница 28: ...cells Connection 4 wire connection to load cells plus shield Maximum cable length 15 Feet Termination DB9 plug on scale Base Specification for Local Scale Load Cell Model No C2X1 Rated Capacity 6 50...

Страница 29: ...NOTES...

Страница 30: ...C100 Series Technical Manual B TEK Scales 1510 Metric Avenue SW Canton OH 44706 Tel 330 471 8900 Fax 330 471 8909 www B TEK com...

Отзывы: